Equipment - Specialty

Image Part Number Description / PDF Quantity Rfq
P3011-INHG

P3011-INHG

Fluke Electronics

VACUUM DEADWEIGHT TESTER (-30 IN

0

P3011-MBAR

P3011-MBAR

Fluke Electronics

VACUUM DEADWEIGHT TESTER (-1000

0

9102S-A-156

9102S-A-156

Fluke Electronics

DRY-WELL HH LOW TEMP

0

FLUKE-1746/B/EUS

FLUKE-1746/B/EUS

Fluke Electronics

POWER QUALITY LOGGER W/ NO IFLEX

0

P5523-20M

P5523-20M

Fluke Electronics

LIQUID TO GAS INTERFACE 20 MPA (

0

9143-E-P-156

9143-E-P-156

Fluke Electronics

DRY-WELL FIELD W/9143-INSE W/BLT

0

P3025-BAR

P3025-BAR

Fluke Electronics

GAS DEADWEIGHT TESTER DUAL VAC/P

0

P3125-KGCM2

P3125-KGCM2

Fluke Electronics

OIL DEADWEIGHT TESTER DUAL RANGE

0

9144-B-P-156

9144-B-P-156

Fluke Electronics

DRY-WELL FIELD W/9144-INSB W/BLT

0

P3113-KGCM2

P3113-KGCM2

Fluke Electronics

OIL DEADWEIGHT TESTER 350 KGF/CM

0

P3214-BAR

P3214-BAR

Fluke Electronics

WATER DEADWEIGHT TESTER 700 BAR

0

9172-E-156

9172-E-156

Fluke Electronics

METROLOGY WELL 425C W/9172-INSE

0

9142-INST

9142-INST

Fluke Electronics

INSERT TEST 9142

0

P3223-MPA

P3223-MPA

Fluke Electronics

WATER DEADWEIGHT TESTER DUAL RAN

0

7109A-P-156

7109A-P-156

Fluke Electronics

7109A PORTABLE CALIBRATION BATH

0

P3014-MPA-P

P3014-MPA-P

Fluke Electronics

GAS DEADWEIGHT TESTER 1 MPA W/ P

0

6531-140M

6531-140M

Fluke Electronics

E-DWT ELECTRONIC DEADWEIGHT TEST

0

P3112-PSI

P3112-PSI

Fluke Electronics

OIL DEADWEIGHT TESTER 2000 PSI

0

9173-D-156

9173-D-156

Fluke Electronics

METROLOGY WELL 700C W/9173-INSD

0

P5510/14-2700G-4/C

P5510/14-2700G-4/C

Fluke Electronics

P5510/P5514 PRESSURE CALIBRATOR

0

Equipment - Specialty

1. Overview

Specialty Test and Measurement Equipment refers to high-precision instruments designed for specific measurement tasks that standard equipment cannot address. These devices are critical in R&D, quality control, and failure analysis across industries. Their importance stems from enabling accurate data acquisition in complex scenarios, such as high-frequency signals, extreme environmental conditions, or nanoscale physical parameters.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Parametric AnalyzersHigh-resolution electrical parameter measurement (e.g., leakage current, capacitance)Semiconductor device characterization
Vector Network Analyzers (VNA)Frequency domain analysis of complex impedance and S-parametersRF/microwave circuit design validation
Thermal Imaging CamerasNon-contact temperature distribution measurement with IR sensorsPower electronics thermal management
Signal Integrity AnalyzersHigh-speed digital signal analysis with time-domain reflectometryPCB trace impedance testing
Material Testing MachinesMechanical property measurement under controlled stress/strainAerospace composite material evaluation

3. Structure and Components

Typical architectures include: - Sensor/transducer array with application-specific probes - Signal conditioning circuitry (amplifiers, filters) - High-speed ADC/DAC modules - FPGA-based processing units - Embedded display or interface ports (USB-C, HDMI, GPIB) - Environmental shielding (EMI/RFI protection enclosures) - Calibration hardware/software modules

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement AccuracyDeviation from true value (e.g., 0.05%)Ensures reliable data for critical decisions
Frequency RangeOperational bandwidth (e.g., DC-67 GHz)Determines applicable use cases
Sampling RateData acquisition speed (e.g., 256 GS/s)Captures high-speed transient events
ResolutionSmallest detectable change (e.g., 16-bit)Enables precision in low-signal environments
Dynamic RangeSignal amplitude measurement span (e.g., 120 dB)Handles wide-ranging signal strengths

5. Application Fields

Primary industries include: - Semiconductor manufacturing (wafer-level testing) - Telecommunications (5G base station validation) - Automotive (EV battery performance analysis) - Aerospace (avionics signal integrity) - Medical devices (implantable sensor calibration) - Academic research (nanotechnology experiments)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Specifications
Keysight TechnologiesN1062A PXIe Oscilloscope63 Gbps sampling rate, 8 channels
Teledyne LeCroyWaveMaster 8Zi-B40 GHz bandwidth, 100 GS/s
Rohde & SchwarzZNBT20 VNA9 kHz-20 GHz, 16-port configuration
Fluke Calibration729 Pressure Controller0.008% accuracy, 9 MPa range
KLA InstrumentsK-Alpha+ XPS10 nm spatial resolution, 0.1 eV energy resolution

7. Selection Recommendations

Key considerations: 1. Match measurement range/sensitivity to application needs 2. Verify compliance with industry standards (e.g., IEEE 1651 for VNAs) 3. Evaluate software ecosystem (API support, automation capabilities) 4. Consider environmental requirements (temperature stability, vibration resistance) 5. Total cost of ownership (calibration frequency, probe replacement costs) 6. Future-proofing (modular architecture, upgrade paths)

8. Industry Trends Analysis

Current trends shaping the sector: - Integration of AI/ML for predictive maintenance and anomaly detection - Miniaturization through MEMS sensor technology (e.g., handheld VNAs) - Increased adoption of O-RAN architecture driving new wireless test requirements - Quantum measurement systems entering commercial markets - Cloud-connected instruments enabling remote monitoring and data analytics - Enhanced EMI/EMC testing solutions for autonomous vehicle development

Application Case: In 5G mmWave testing, Keysight's UXM 5G Wireless Test Set combines parametric and protocol testing in a single platform, reducing validation time by 40% compared to traditional methods.

RFQ BOM Call Skype Email