Equipment - Specialty

Image Part Number Description / PDF Quantity Rfq
9170-E-156

9170-E-156

Fluke Electronics

METROLOGY WELL -45C W/9170-INSE

0

P3800C

P3800C

Fluke Electronics

HIGH PRESSURE COMPARISON TEST PU

0

9173-A-R-156

9173-A-R-156

Fluke Electronics

METROLOGY WELL 700C W/9173-INSA

0

P3015-MPA-P

P3015-MPA-P

Fluke Electronics

GAS DEADWEIGHT TESTER 3.5 MPA W/

0

P3025-KGCM2

P3025-KGCM2

Fluke Electronics

GAS DEADWEIGHT TESTER DUAL VAC/P

0

P3011-MMHG-P

P3011-MMHG-P

Fluke Electronics

VACUUM DEADWEIGHT TESTER (-760 M

0

9143-DW-P-156

9143-DW-P-156

Fluke Electronics

DRY-WELL FIELD NO INSERT W/BLT-I

0

9144-F-P-156

9144-F-P-156

Fluke Electronics

DRY-WELL FIELD W/9144-INSF W/BLT

0

9150-D-156

9150-D-156

Fluke Electronics

FURNACE 12000C TC W/3150-5 115V

0

P3112-KGCM2

P3112-KGCM2

Fluke Electronics

OIL DEADWEIGHT TESTER 140 KGF/CM

0

P3011-MMHG

P3011-MMHG

Fluke Electronics

VACUUM DEADWEIGHT TESTER (-760 M

0

P3840-PSI

P3840-PSI

Fluke Electronics

OIL DEADWEIGHT TESTER 40K PSI

0

FLUKE-717 1000G

FLUKE-717 1000G

Fluke Electronics

PRESSURE CALIBRATOR 1000 PSIG

0

9103-DW-156

9103-DW-156

Fluke Electronics

DRY-WELL -25C FIELD NO INSERT 11

0

PM200-G10M

PM200-G10M

Fluke Electronics

PRESSURE MEASUREMENT MODULE 0 TO

0

P3830-BAR

P3830-BAR

Fluke Electronics

OIL DEADWEIGHT TESTER 2000 BAR

0

9172-C-156

9172-C-156

Fluke Electronics

METROLOGY WELL 425C W/9172-INSC

0

FLUKE-435-II/BASIC

FLUKE-435-II/BASIC

Fluke Electronics

PQ AND ENERGY ANALYZER W/O PROBE

0

9103-D-156

9103-D-156

Fluke Electronics

DRY-WELL -25C FIELD W/ 3103-6 11

0

P5514-2700G-3/C

P5514-2700G-3/C

Fluke Electronics

P5514 HYDRAULIC CALIBRATOR 70 MP

0

Equipment - Specialty

1. Overview

Specialty Test and Measurement Equipment refers to high-precision instruments designed for specific measurement tasks that standard equipment cannot address. These devices are critical in R&D, quality control, and failure analysis across industries. Their importance stems from enabling accurate data acquisition in complex scenarios, such as high-frequency signals, extreme environmental conditions, or nanoscale physical parameters.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Parametric AnalyzersHigh-resolution electrical parameter measurement (e.g., leakage current, capacitance)Semiconductor device characterization
Vector Network Analyzers (VNA)Frequency domain analysis of complex impedance and S-parametersRF/microwave circuit design validation
Thermal Imaging CamerasNon-contact temperature distribution measurement with IR sensorsPower electronics thermal management
Signal Integrity AnalyzersHigh-speed digital signal analysis with time-domain reflectometryPCB trace impedance testing
Material Testing MachinesMechanical property measurement under controlled stress/strainAerospace composite material evaluation

3. Structure and Components

Typical architectures include: - Sensor/transducer array with application-specific probes - Signal conditioning circuitry (amplifiers, filters) - High-speed ADC/DAC modules - FPGA-based processing units - Embedded display or interface ports (USB-C, HDMI, GPIB) - Environmental shielding (EMI/RFI protection enclosures) - Calibration hardware/software modules

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement AccuracyDeviation from true value (e.g., 0.05%)Ensures reliable data for critical decisions
Frequency RangeOperational bandwidth (e.g., DC-67 GHz)Determines applicable use cases
Sampling RateData acquisition speed (e.g., 256 GS/s)Captures high-speed transient events
ResolutionSmallest detectable change (e.g., 16-bit)Enables precision in low-signal environments
Dynamic RangeSignal amplitude measurement span (e.g., 120 dB)Handles wide-ranging signal strengths

5. Application Fields

Primary industries include: - Semiconductor manufacturing (wafer-level testing) - Telecommunications (5G base station validation) - Automotive (EV battery performance analysis) - Aerospace (avionics signal integrity) - Medical devices (implantable sensor calibration) - Academic research (nanotechnology experiments)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Specifications
Keysight TechnologiesN1062A PXIe Oscilloscope63 Gbps sampling rate, 8 channels
Teledyne LeCroyWaveMaster 8Zi-B40 GHz bandwidth, 100 GS/s
Rohde & SchwarzZNBT20 VNA9 kHz-20 GHz, 16-port configuration
Fluke Calibration729 Pressure Controller0.008% accuracy, 9 MPa range
KLA InstrumentsK-Alpha+ XPS10 nm spatial resolution, 0.1 eV energy resolution

7. Selection Recommendations

Key considerations: 1. Match measurement range/sensitivity to application needs 2. Verify compliance with industry standards (e.g., IEEE 1651 for VNAs) 3. Evaluate software ecosystem (API support, automation capabilities) 4. Consider environmental requirements (temperature stability, vibration resistance) 5. Total cost of ownership (calibration frequency, probe replacement costs) 6. Future-proofing (modular architecture, upgrade paths)

8. Industry Trends Analysis

Current trends shaping the sector: - Integration of AI/ML for predictive maintenance and anomaly detection - Miniaturization through MEMS sensor technology (e.g., handheld VNAs) - Increased adoption of O-RAN architecture driving new wireless test requirements - Quantum measurement systems entering commercial markets - Cloud-connected instruments enabling remote monitoring and data analytics - Enhanced EMI/EMC testing solutions for autonomous vehicle development

Application Case: In 5G mmWave testing, Keysight's UXM 5G Wireless Test Set combines parametric and protocol testing in a single platform, reducing validation time by 40% compared to traditional methods.

RFQ BOM Call Skype Email
Top