Equipment - Specialty

Image Part Number Description / PDF Quantity Rfq
7102-156

7102-156

Fluke Electronics

MICRO-BATH -5 TO 125C 110V 50/60

0

6109A-156

6109A-156

Fluke Electronics

6109A PORTABLE CALIBRATION BATH,

0

9171-F-R-156

9171-F-R-156

Fluke Electronics

METROLOGY WELL -30C W/9171-INSF

0

FLK-3561 FC 3YR

FLK-3561 FC 3YR

Fluke Electronics

VIBRATION SENSOR 3YR EXPANSION K

0

9190A-A-P-156

9190A-A-P-156

Fluke Electronics

DRY-WELL ULTRA-COLD INSRT-A BLT-

0

P3223-KGCM2

P3223-KGCM2

Fluke Electronics

WATER DEADWEIGHT TESTER DUAL RAN

0

P3013-KPA-P

P3013-KPA-P

Fluke Electronics

GAS DEADWEIGHT TESTER 200 KPA W/

0

FLUKE-N4K 3PP52IB

FLUKE-N4K 3PP52IB

Fluke Electronics

3 PH N4K POWER ANALYZER W/52BP

0

FLUKE-931 ESP

FLUKE-931 ESP

Fluke Electronics

COMBO TACHOMETER

0

P3025-PSI-P

P3025-PSI-P

Fluke Electronics

GAS DEADWEIGHT TESTER DUAL VAC/P

0

9172-A-156

9172-A-156

Fluke Electronics

METROLOGY WELL 425C W/9172-INSA

0

FLUKE-717 10000G

FLUKE-717 10000G

Fluke Electronics

PRESSURE CALIBRATOR 10000 PSIG

0

FLUKE-N5K 6PP64IPR

FLUKE-N5K 6PP64IPR

Fluke Electronics

6 PH N5K POWER ANALYZER W/64/IFC

0

9150-B-156

9150-B-156

Fluke Electronics

FURNACE 1200C TC W/3150-3 110V 5

0

9150-C-156

9150-C-156

Fluke Electronics

FURNACE 1200C TC W/3150-4 110V 5

0

FLUKE-N5K 3PP64IR

FLUKE-N5K 3PP64IR

Fluke Electronics

3 PH N5K POWER ANALYZER W/64/IFC

0

9143-D-156

9143-D-156

Fluke Electronics

DRY-WELL MID-TEMP FIELD W/9143-I

0

PM200-G4M

PM200-G4M

Fluke Electronics

PRESSURE MEASUREMENT MODULE 0 TO

0

9142-B-156

9142-B-156

Fluke Electronics

DRY-WELL LOW-TEMP FIELD W/9142-I

0

P3111-KGCM2

P3111-KGCM2

Fluke Electronics

OIL DEADWEIGHT TESTER 35 KGF/CM2

0

Equipment - Specialty

1. Overview

Specialty Test and Measurement Equipment refers to high-precision instruments designed for specific measurement tasks that standard equipment cannot address. These devices are critical in R&D, quality control, and failure analysis across industries. Their importance stems from enabling accurate data acquisition in complex scenarios, such as high-frequency signals, extreme environmental conditions, or nanoscale physical parameters.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Parametric AnalyzersHigh-resolution electrical parameter measurement (e.g., leakage current, capacitance)Semiconductor device characterization
Vector Network Analyzers (VNA)Frequency domain analysis of complex impedance and S-parametersRF/microwave circuit design validation
Thermal Imaging CamerasNon-contact temperature distribution measurement with IR sensorsPower electronics thermal management
Signal Integrity AnalyzersHigh-speed digital signal analysis with time-domain reflectometryPCB trace impedance testing
Material Testing MachinesMechanical property measurement under controlled stress/strainAerospace composite material evaluation

3. Structure and Components

Typical architectures include: - Sensor/transducer array with application-specific probes - Signal conditioning circuitry (amplifiers, filters) - High-speed ADC/DAC modules - FPGA-based processing units - Embedded display or interface ports (USB-C, HDMI, GPIB) - Environmental shielding (EMI/RFI protection enclosures) - Calibration hardware/software modules

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement AccuracyDeviation from true value (e.g., 0.05%)Ensures reliable data for critical decisions
Frequency RangeOperational bandwidth (e.g., DC-67 GHz)Determines applicable use cases
Sampling RateData acquisition speed (e.g., 256 GS/s)Captures high-speed transient events
ResolutionSmallest detectable change (e.g., 16-bit)Enables precision in low-signal environments
Dynamic RangeSignal amplitude measurement span (e.g., 120 dB)Handles wide-ranging signal strengths

5. Application Fields

Primary industries include: - Semiconductor manufacturing (wafer-level testing) - Telecommunications (5G base station validation) - Automotive (EV battery performance analysis) - Aerospace (avionics signal integrity) - Medical devices (implantable sensor calibration) - Academic research (nanotechnology experiments)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Specifications
Keysight TechnologiesN1062A PXIe Oscilloscope63 Gbps sampling rate, 8 channels
Teledyne LeCroyWaveMaster 8Zi-B40 GHz bandwidth, 100 GS/s
Rohde & SchwarzZNBT20 VNA9 kHz-20 GHz, 16-port configuration
Fluke Calibration729 Pressure Controller0.008% accuracy, 9 MPa range
KLA InstrumentsK-Alpha+ XPS10 nm spatial resolution, 0.1 eV energy resolution

7. Selection Recommendations

Key considerations: 1. Match measurement range/sensitivity to application needs 2. Verify compliance with industry standards (e.g., IEEE 1651 for VNAs) 3. Evaluate software ecosystem (API support, automation capabilities) 4. Consider environmental requirements (temperature stability, vibration resistance) 5. Total cost of ownership (calibration frequency, probe replacement costs) 6. Future-proofing (modular architecture, upgrade paths)

8. Industry Trends Analysis

Current trends shaping the sector: - Integration of AI/ML for predictive maintenance and anomaly detection - Miniaturization through MEMS sensor technology (e.g., handheld VNAs) - Increased adoption of O-RAN architecture driving new wireless test requirements - Quantum measurement systems entering commercial markets - Cloud-connected instruments enabling remote monitoring and data analytics - Enhanced EMI/EMC testing solutions for autonomous vehicle development

Application Case: In 5G mmWave testing, Keysight's UXM 5G Wireless Test Set combines parametric and protocol testing in a single platform, reducing validation time by 40% compared to traditional methods.

RFQ BOM Call Skype Email