Equipment - Power Supplies (Test, Bench)

Image Part Number Description / PDF Quantity Rfq
SL200-7.5/UI+LXI

SL200-7.5/UI+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 1.5 KW

100

KLP 600-4

KLP 600-4

Kepco Power

POWER SUPPLY 1200W

10

BOP 36-28MG

BOP 36-28MG

Kepco Power

1000 WATT POWER SUPPLY

10

ATE 75-0.7DML

ATE 75-0.7DML

Kepco Power

POWER SUPPLY RACK MNT 50W LCD LO

10

Z60-10-IS510-U

Z60-10-IS510-U

TDK-Lambda, Inc.

AC/DC PROGRAMMABLE SUPPLY 0-60V

0

BOP 50-2DC

BOP 50-2DC

Kepco Power

POWER SUPPLY RACK MNT 100W CAPAC

10

PLH250-P

PLH250-P

AIMtti

PWR SUPP SNGL OUT 0-250V0-0.375A

0

ZUP120-3.6/U

ZUP120-3.6/U

TDK-Lambda, Inc.

PWR SUP BENCH PROG 0-120V 432W

8

KLN 100-15E

KLN 100-15E

Kepco Power

POWER SUPPLY 1500W + LXI INTERF

10

Z320-0.65-LAN-U

Z320-0.65-LAN-U

TDK-Lambda, Inc.

PWR SUPPLY OUTPUT 0-320V 0-.65A

0

BOP 20-5D-4886

BOP 20-5D-4886

Kepco Power

POWER SUPPLY RACK MNT 100W GPIB/

10

ATE 75-3DML

ATE 75-3DML

Kepco Power

POWER SUPPLY RACK MNT 250W LCD L

10

Z160-1.3-IS420-U

Z160-1.3-IS420-U

TDK-Lambda, Inc.

PWR SUPPLY OUTPUT 0-160V 0-1.3A

0

9115

9115

B&K Precision

AC/DC CONVERTER 80V 60A 1200W

0

SL250-24/208+LXI

SL250-24/208+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 6 KW 0

100

PS/EY015R080-22

PS/EY015R080-22

XP Power

AC-DC HV PSU, 1200W, REVERSE POL

0

ATE 75-15DM

ATE 75-15DM

Kepco Power

POWER SUPPLY RACK MNT 1000W LCD

10

55-000030-01

55-000030-01

Versatile Power

PWR SUP PROG 30VDC 33A 600W

100

KLR 300-8ER

KLR 300-8ER

Kepco Power

POWER SUPPLY 2400W + LXI + RODC

10

BOP 20-50MGL

BOP 20-50MGL

Kepco Power

1000 WATT POWER SUPPLY GPIB CONT

10

Equipment - Power Supplies (Test, Bench)

1. Overview

Bench power supplies are adjustable DC or AC power sources designed for testing, troubleshooting, and development in electronic engineering. They provide stable, precise, and controllable electrical power to devices under test (DUTs) in laboratory, production, and field service environments. Their importance lies in ensuring product reliability, validating circuit performance, and supporting R&D workflows across industries.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Linear Power SuppliesLow noise, high stability, fast transient responseLaboratory testing of analog circuits
Switching Power SuppliesHigh efficiency (>80%), wide input range, compact sizeAutomated production line testing
Programmable Power SuppliesComputer-controlled output, waveform generation, data loggingAutomotive electronics validation
Multi-channel Power SuppliesIndependent voltage/current control for multiple outputsTesting IoT devices with multiple rails

3. Structure and Components

Typical bench power supplies include:

  • Metallic enclosure with ventilation slots
  • AC/DC power module (linear/regenerative topology)
  • Control panel with digital/analog interfaces
  • Output terminals (banana jacks, binding posts)
  • Active cooling system (fan/heat sink)
  • Communication ports (USB/LAN/GPIB)

4. Key Technical Specifications

ParameterDescriptionImportance
Output Voltage Range0-200V (single/multi-range options)Determines compatibility with DUT requirements
Current Resolution1mA-10 A precisionImpacts test accuracy for low-power devices
Load Regulation<0.01% change under varying loadEnsures stable output during dynamic testing
Ripple & Noise<3mVpp @ 20MHz bandwidthCritical for sensitive analog circuit testing
Transient Response Time10-100 s recovery timeMeasures stability during sudden load changes

5. Application Fields

  • Electronics manufacturing (IC testing, PCB validation)
  • Telecom equipment (5G base station power simulation)
  • Automotive R&D (ECU power cycling tests)
  • Aerospace (avionics power quality analysis)
  • Educational labs (student project prototyping)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN6700 Modular Power SystemHot-swappable modules, 16-bit resolution
Teledyne LeCroyTS-8080800W regenerative AC/DC source
Siglent TechnologiesSPD1168X16-bit touchscreen control, list mode
Chroma Systems62000P SeriesGrid simulation, energy recovery

7. Selection Recommendations

Key considerations:

  • Match output specs to DUT's maximum power requirements
  • Choose appropriate control interface (analog/digital)
  • Assess thermal management needs for continuous operation
  • Prioritize calibration features for traceable measurements

Example: For battery simulation applications, select a bidirectional power supply with dynamic profiling capabilities.

8. Industry Trends

Current development trends include:

  • Integration of AI-based predictive maintenance
  • Higher power density (3-5W/cm ) through GaN technology
  • Adoption of PMBus for smart power system management
  • Expansion of 800V DC test capabilities for EV applications
  • Cloud-connected power supplies for remote monitoring

RFQ BOM Call Skype Email