Equipment - Power Supplies (Test, Bench)

Image Part Number Description / PDF Quantity Rfq
Z36-24-LAN-L-U

Z36-24-LAN-L-U

TDK-Lambda, Inc.

AC/DC PROGRAMMABLE SUPPLY 0-36V

3

Z36-24-LAN-U

Z36-24-LAN-U

TDK-Lambda, Inc.

AC/DC PROGRAMMABLE SUPPLY 0-36V

1

SL1000-1.5/208+LXI

SL1000-1.5/208+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 1.5 KW

100

ZUP20-40/U

ZUP20-40/U

TDK-Lambda, Inc.

PWR SUP BENCH PROG 0-20V 800W

1

SL1500-1/UI+LXI

SL1500-1/UI+LXI

Magna-Power Electronics

PWR SUP 0-1500VDC 1500W 0-1A

98

SL40-150/480+LXI

SL40-150/480+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 6 KW 0

100

SL32-46/480+LXI

SL32-46/480+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 1.5 KW

100

SL32-250/480+LXI

SL32-250/480+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 8 KW 0

99

1368

1368

Global Specialties

TRIPLE OUTPUT PROGRAMMABLE DC PO

3

ATE 6-5DML

ATE 6-5DML

Kepco Power

POWER SUPPLY RACK MNT 50W LCD LO

10

KLN 30-25

KLN 30-25

Kepco Power

POWER SUPPLY 750W

10

ZUP36-6/LU

ZUP36-6/LU

TDK-Lambda, Inc.

PWR SUP BENCH PROG 0-36V 216W

1

Z36-18-U

Z36-18-U

TDK-Lambda, Inc.

AC/DC PROGRAMMABLE SUPPLY 0-36V

0

KLN 12.5-60

KLN 12.5-60

Kepco Power

POWER SUPPLY 750W

10

ATE 100-0.5DML

ATE 100-0.5DML

Kepco Power

POWER SUPPLY RACK MNT 50W LCD LO

10

BOP 100-2DL

BOP 100-2DL

Kepco Power

POWER SUPPLY RACK MNT 200W INDUC

10

SL1250-6.4/208+LXI

SL1250-6.4/208+LXI

Magna-Power Electronics

PWR SUP 0-1250VDC 8000W 0-6.4A

0

SL375-4/208+LXI

SL375-4/208+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 1.5 KW

100

QL355P SII

QL355P SII

AIMtti

PWR SUPP SNGL OUT 0-35V0-5A * LX

0

BOP 20-10D-802E

BOP 20-10D-802E

Kepco Power

POWER SUPPLY RACK MNT 200W ETHER

10

Equipment - Power Supplies (Test, Bench)

1. Overview

Bench power supplies are adjustable DC or AC power sources designed for testing, troubleshooting, and development in electronic engineering. They provide stable, precise, and controllable electrical power to devices under test (DUTs) in laboratory, production, and field service environments. Their importance lies in ensuring product reliability, validating circuit performance, and supporting R&D workflows across industries.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Linear Power SuppliesLow noise, high stability, fast transient responseLaboratory testing of analog circuits
Switching Power SuppliesHigh efficiency (>80%), wide input range, compact sizeAutomated production line testing
Programmable Power SuppliesComputer-controlled output, waveform generation, data loggingAutomotive electronics validation
Multi-channel Power SuppliesIndependent voltage/current control for multiple outputsTesting IoT devices with multiple rails

3. Structure and Components

Typical bench power supplies include:

  • Metallic enclosure with ventilation slots
  • AC/DC power module (linear/regenerative topology)
  • Control panel with digital/analog interfaces
  • Output terminals (banana jacks, binding posts)
  • Active cooling system (fan/heat sink)
  • Communication ports (USB/LAN/GPIB)

4. Key Technical Specifications

ParameterDescriptionImportance
Output Voltage Range0-200V (single/multi-range options)Determines compatibility with DUT requirements
Current Resolution1mA-10 A precisionImpacts test accuracy for low-power devices
Load Regulation<0.01% change under varying loadEnsures stable output during dynamic testing
Ripple & Noise<3mVpp @ 20MHz bandwidthCritical for sensitive analog circuit testing
Transient Response Time10-100 s recovery timeMeasures stability during sudden load changes

5. Application Fields

  • Electronics manufacturing (IC testing, PCB validation)
  • Telecom equipment (5G base station power simulation)
  • Automotive R&D (ECU power cycling tests)
  • Aerospace (avionics power quality analysis)
  • Educational labs (student project prototyping)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN6700 Modular Power SystemHot-swappable modules, 16-bit resolution
Teledyne LeCroyTS-8080800W regenerative AC/DC source
Siglent TechnologiesSPD1168X16-bit touchscreen control, list mode
Chroma Systems62000P SeriesGrid simulation, energy recovery

7. Selection Recommendations

Key considerations:

  • Match output specs to DUT's maximum power requirements
  • Choose appropriate control interface (analog/digital)
  • Assess thermal management needs for continuous operation
  • Prioritize calibration features for traceable measurements

Example: For battery simulation applications, select a bidirectional power supply with dynamic profiling capabilities.

8. Industry Trends

Current development trends include:

  • Integration of AI-based predictive maintenance
  • Higher power density (3-5W/cm ) through GaN technology
  • Adoption of PMBus for smart power system management
  • Expansion of 800V DC test capabilities for EV applications
  • Cloud-connected power supplies for remote monitoring

RFQ BOM Call Skype Email