Equipment - Power Supplies (Test, Bench)

Image Part Number Description / PDF Quantity Rfq
KWR103

KWR103

SRA Soldering Products

KORAD KWR103 PROGRAMMABLE DC POW

0

ATE 15-50DML

ATE 15-50DML

Kepco Power

POWER SUPPLY RACK MNT 1000W LCD

10

KLR 150-16ER

KLR 150-16ER

Kepco Power

POWER SUPPLY 2400W + LXI + RODC

10

Z320-0.65-IEEE-U

Z320-0.65-IEEE-U

TDK-Lambda, Inc.

PWR SUPPLY OUTPUT 0-320V 0-.65A

0

SL10-150/480+LXI

SL10-150/480+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 1.5 KW

100

Z60-7-U

Z60-7-U

TDK-Lambda, Inc.

AC/DC PROGRAMMABLE SUPPLY 0-60V

28

KLN 50-60E

KLN 50-60E

Kepco Power

POWER SUPPLY 3000W + LXI INTERF

10

1550-220V

1550-220V

B&K Precision

PWR SPLY 36V 0-3A W/USB 220V-IN

24

BOP 20-10DL4886

BOP 20-10DL4886

Kepco Power

POWER SUPPLY RACK MNT 200W INDUC

10

SL200-20/208+LXI

SL200-20/208+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 4 KW 0

100

CPX400SA

CPX400SA

AIMtti

PWR SUPP SNGL OUT 420W &#39

0

1790

1790

B&K Precision

POWER SPLY DC LINEAR 0-32V 0-20A

0

ZUP60-7/U

ZUP60-7/U

TDK-Lambda, Inc.

PWR SUP BENCH PROG 0-60V 420W

10

BOP 100-1DL802E

BOP 100-1DL802E

Kepco Power

POWER SUPPLY RACK MNT 100W INDUC

10

SL32-125/208+LXI

SL32-125/208+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 4 KW 0

100

SL1250-4.8/480+LXI

SL1250-4.8/480+LXI

Magna-Power Electronics

PWR SUP 0-1250VDC 6000W 0-4.8A

0

SL125-20/208+LXI

SL125-20/208+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 2.6 KW

100

SL16-250/208+LXI

SL16-250/208+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 4 KW 0

100

KLN 600-2.5E

KLN 600-2.5E

Kepco Power

POWER SUPPLY 1500W + LXI INTERF

3

T3PS11230

T3PS11230

Teledyne LeCroy

PWR SPLY SNGL OUT 0-12V 0-30A SW

0

Equipment - Power Supplies (Test, Bench)

1. Overview

Bench power supplies are adjustable DC or AC power sources designed for testing, troubleshooting, and development in electronic engineering. They provide stable, precise, and controllable electrical power to devices under test (DUTs) in laboratory, production, and field service environments. Their importance lies in ensuring product reliability, validating circuit performance, and supporting R&D workflows across industries.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Linear Power SuppliesLow noise, high stability, fast transient responseLaboratory testing of analog circuits
Switching Power SuppliesHigh efficiency (>80%), wide input range, compact sizeAutomated production line testing
Programmable Power SuppliesComputer-controlled output, waveform generation, data loggingAutomotive electronics validation
Multi-channel Power SuppliesIndependent voltage/current control for multiple outputsTesting IoT devices with multiple rails

3. Structure and Components

Typical bench power supplies include:

  • Metallic enclosure with ventilation slots
  • AC/DC power module (linear/regenerative topology)
  • Control panel with digital/analog interfaces
  • Output terminals (banana jacks, binding posts)
  • Active cooling system (fan/heat sink)
  • Communication ports (USB/LAN/GPIB)

4. Key Technical Specifications

ParameterDescriptionImportance
Output Voltage Range0-200V (single/multi-range options)Determines compatibility with DUT requirements
Current Resolution1mA-10 A precisionImpacts test accuracy for low-power devices
Load Regulation<0.01% change under varying loadEnsures stable output during dynamic testing
Ripple & Noise<3mVpp @ 20MHz bandwidthCritical for sensitive analog circuit testing
Transient Response Time10-100 s recovery timeMeasures stability during sudden load changes

5. Application Fields

  • Electronics manufacturing (IC testing, PCB validation)
  • Telecom equipment (5G base station power simulation)
  • Automotive R&D (ECU power cycling tests)
  • Aerospace (avionics power quality analysis)
  • Educational labs (student project prototyping)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN6700 Modular Power SystemHot-swappable modules, 16-bit resolution
Teledyne LeCroyTS-8080800W regenerative AC/DC source
Siglent TechnologiesSPD1168X16-bit touchscreen control, list mode
Chroma Systems62000P SeriesGrid simulation, energy recovery

7. Selection Recommendations

Key considerations:

  • Match output specs to DUT's maximum power requirements
  • Choose appropriate control interface (analog/digital)
  • Assess thermal management needs for continuous operation
  • Prioritize calibration features for traceable measurements

Example: For battery simulation applications, select a bidirectional power supply with dynamic profiling capabilities.

8. Industry Trends

Current development trends include:

  • Integration of AI-based predictive maintenance
  • Higher power density (3-5W/cm ) through GaN technology
  • Adoption of PMBus for smart power system management
  • Expansion of 800V DC test capabilities for EV applications
  • Cloud-connected power supplies for remote monitoring

RFQ BOM Call Skype Email
Top