Accessories

Image Part Number Description / PDF Quantity Rfq
BC430/820

BC430/820

Fluke Electronics

POWER ADAPTER SMPS FLUKE-430-SER

0

C12A

C12A

Fluke Electronics

CARRYING CASE SOFT

0

BP130

BP130

Fluke Electronics

RECHARGEABLE BATTERY PACK NI-MH

0

FLUKE-700BCA

FLUKE-700BCA

Fluke Electronics

BAR CODE ADAPTER

0

FLK-XLENS/MACRO2

FLK-XLENS/MACRO2

Fluke Electronics

INFRARED CLOSE-UP LENS

0

PR1006ACI

PR1006ACI

Fluke Electronics

ACCESSORY

0

PR1506ACI

PR1506ACI

Fluke Electronics

ACCESSORY

0

SC860

SC860

Fluke Electronics

SOFTWARE & OPTICAL CABLE

0

FOS-850/1300

FOS-850/1300

Fluke Electronics

FIBER OPTIC LIGHT SOURCE

0

1743/44 POLESET

1743/44 POLESET

Fluke Electronics

POLE MOUNTING KIT FOR 1743/44

0

DR80/NAP

DR80/NAP

Fluke Electronics

METER DISPLAY

0

C25/NAP

C25/NAP

Fluke Electronics

CARRYING CASE

0

105123

105123

Fluke Electronics

CASE CARRY FLEXCAM

0

PR1004MACI

PR1004MACI

Fluke Electronics

ACCESSORY

0

C100/NAP

C100/NAP

Fluke Electronics

CARRYING CASE

0

2633-RF

2633-RF

Fluke Electronics

OPTION FACTORY INSTALL WIRELESS

0

FLK-XPOWER PLUG

FLK-XPOWER PLUG

Fluke Electronics

POWER PLUG 15V 5 EXTENSIONS

0

PR3003ACI

PR3003ACI

Fluke Electronics

ACCESSORY

0

DR80/BB

DR80/BB

Fluke Electronics

METER DISPLAY

0

PR1203MACI

PR1203MACI

Fluke Electronics

ACCESSORY

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments