Accessories

Image Part Number Description / PDF Quantity Rfq
CWS3830-BAR

CWS3830-BAR

Fluke Electronics

CONVERSION WEIGHT SET P3830 BAR

0

2373-LTC

2373-LTC

Fluke Electronics

ADAPTER LEMO TO UNIVERSAL TC (TC

0

CWS3123-MPA

CWS3123-MPA

Fluke Electronics

CONVERSION WEIGHT SET P3123/P312

0

4112830

4112830

Fluke Electronics

SILVERCAREPLAN-GROUP3-4YR

0

C100

C100

Fluke Electronics

UNIVERSAL CARRYING CASE

0

SW90W/034EFG

SW90W/034EFG

Fluke Electronics

FLUKEVIEW V4.0 EFG CD-ROM

0

884X-512M

884X-512M

Fluke Electronics

USB MEMORY 512M

0

C800

C800

Fluke Electronics

CASE METER AND ACCESSORY HARD

0

FLK-CNX C3003

FLK-CNX C3003

Fluke Electronics

3 COMPARTMENT SOFT CASE

0

CAMO-C37

CAMO-C37

Fluke Electronics

CAMO CARRYING CASE CLAMPS T5

0

FLK-VT04-CHARGER

FLK-VT04-CHARGER

Fluke Electronics

VT04 USB CHARGER

0

PM8907/808

PM8907/808

Fluke Electronics

POWER ADAPTER/BATT CHARGER-UNIV

0

PAC91

PAC91

Fluke Electronics

CABLE PRINT ADAPTER

0

FOM

FOM

Fluke Electronics

FIBER OPTIC METER

0

C3004IND

C3004IND

Fluke Electronics

SOFT TOOL BAG FOR IND KIT

0

FLK-TI-SBC3

FLK-TI-SBC3

Fluke Electronics

SMART BATTERY CHARGER 3

0

FLK-TI-SBP

FLK-TI-SBP

Fluke Electronics

IR SMART BATTERY PACK

0

FLK-CNX PC3000

FLK-CNX PC3000

Fluke Electronics

WIRELESS PC ADAPTER

0

4112809

4112809

Fluke Electronics

GOLDCAREPLAN-GROUP3-4YR

0

BC190/808

BC190/808

Fluke Electronics

BATTERY CHARGER UNIVERSAL

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top