Accessories

Image Part Number Description / PDF Quantity Rfq
NORMA LG SHUNT/CBL

NORMA LG SHUNT/CBL

Fluke Electronics

CABLES FOR HIGH CURRENT SHUNTS

0

SV225

SV225

Fluke Electronics

ADAPTER STRAY VOLTAGE

0

PK-ADPTR-P3K

PK-ADPTR-P3K

Fluke Electronics

ADAPTOR SET P3000 TEST PORT 20 M

0

2638A-RLY

2638A-RLY

Fluke Electronics

EXTRA RELAY CARD REPLACEMENT

0

CWS3840-BAR

CWS3840-BAR

Fluke Electronics

CONVERSION WEIGHT SET P3840 BAR

0

2627-H

2627-H

Fluke Electronics

KIT THERMO-HYGROMETER SPARE PROB

0

4180-CASE

4180-CASE

Fluke Electronics

CASE CARRYING 4180/4181

0

TQAERO

TQAERO

Fluke Electronics

SOFTWARE TQAERO

0

2361-156

2361-156

Fluke Electronics

ADAPTER SPARE AC 12V (1521/1522)

0

700HPF-MET

700HPF-MET

Fluke Electronics

HIGH PRESSURE PREMIUM FITTINGS M

0

FLUKE-700TTH5K

FLUKE-700TTH5K

Fluke Electronics

PREMIUM PRESS TRANSMITTER TEST H

0

9173-INSE

9173-INSE

Fluke Electronics

INSERT E 9173 METRIC 0.25 IN REF

0

S2P-TI/R-105

S2P-TI/R-105

Fluke Electronics

2 YR SILVER CAREPLAN TI105 TIR10

0

TI-TRIPOD

TI-TRIPOD

Fluke Electronics

TRIPOD MTG ACCESSORY/HOLDER

0

PK-ADPTR-HC20

PK-ADPTR-HC20

Fluke Electronics

ADAPTOR SET STD TEST PORT 20 MPA

0

Y525

Y525

Fluke Electronics

RACK MOUNT KIT

0

FLK-3.8MM/1M PROBE

FLK-3.8MM/1M PROBE

Fluke Electronics

3.8 MM SCOPE WITH A 1M PROBE FOR

0

P5540

P5540

Fluke Electronics

ADAPTER SET - METRIC

0

9190-CASE

9190-CASE

Fluke Electronics

CASE 9190 CARRYING

0

9190-INSA

9190-INSA

Fluke Electronics

INSERT A 9190 MISC HLS

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top