Accessories

Image Part Number Description / PDF Quantity Rfq
9190-INSB

9190-INSB

Fluke Electronics

INSERT B 9190 CMP HLS

0

9142-CASE

9142-CASE

Fluke Electronics

CASE 9142-4 CARRYING

0

CWS3113-PSI

CWS3113-PSI

Fluke Electronics

CONVERSION WEIGHT SET P3113/P311

0

FLUKE-700-IV

FLUKE-700-IV

Fluke Electronics

CURRENT SHUNT

0

SCC 198

SCC 198

Fluke Electronics

KIT AUTOMOTIVE ACC 190 SERIES

0

CWS3031-KPA

CWS3031-KPA

Fluke Electronics

CONVERSION WEIGHT SET P3031 KPA

0

3141-2

3141-2

Fluke Electronics

INSERT A AL-BRNZ W/ MISC HOLES (

0

3103-3

3103-3

Fluke Electronics

INSERT B W/ COMPARISON HOLES (91

0

9171-INSZ

9171-INSZ

Fluke Electronics

INSERT BLANK 9171

0

NORMA V & I CABLES

NORMA V & I CABLES

Fluke Electronics

MEASUREMENT CABLE SET

0

9172-INSB

9172-INSB

Fluke Electronics

INSERT B 9172 CMP HLS

0

NORMA 32A CABLES

NORMA 32A CABLES

Fluke Electronics

CABLES FOR 32A PLANAR SHUNT

0

NORMA 10A SHUNT

NORMA 10A SHUNT

Fluke Electronics

TRIAXIAL EXTERNAL SHUNT

0

9173-INSF

9173-INSF

Fluke Electronics

INSERT F 9173 METRIC 0.25 IN REF

0

CWS3111-MPA

CWS3111-MPA

Fluke Electronics

CONVERSION WEIGHT SET P3111/P321

0

SCP-TIX520

SCP-TIX520

Fluke Electronics

SILVER CAREPLAN TIX520 1 YR

0

FLUKE-BTL20ANG

FLUKE-BTL20ANG

Fluke Electronics

BATTERY ANALYZER TEST PROBE SET

1

IEEE519/REPORT

IEEE519/REPORT

Fluke Electronics

SOFTWARE LICENSE FOR IEEE519 REP

0

P5541

P5541

Fluke Electronics

ADAPTER SET - BSP

0

P5515SK

P5515SK

Fluke Electronics

SEAL KIT P5515

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top