Accessories

Image Part Number Description / PDF Quantity Rfq
72-039

72-039

NTE Electronics, Inc.

4MM PANEL SOCKET GREEN

701

72-182-0

72-182-0

NTE Electronics, Inc.

BANANA COUPLER INSUL BLK

552

TLKB1

TLKB1

B&K Precision

4-WIRE KELVIN CLIP TEST FIXTURE

0

BU-62-6

BU-62-6

Mueller Electric Co.

INSULATOR-ALLIGATOR CLIP PVC BLU

3804744

CT4140A-1.5A

CT4140A-1.5A

Cal Test Electronics

4MM INLINE FUSE ADAPTER, 1KV CAT

17

9326

9326

Fluke Electronics

CASE CARRYING (5577 AND 2-300 MM

0

PK116

PK116

Teledyne LeCroy

PP006 SPARE ACCES KIT

2

CBL-S3

CBL-S3

AIMtti

SERIAL CABLE FOR PC1604 AIM TTI

0

Y402810K0000V0L

Y402810K0000V0L

VPG Foil

RES 10K OHM .2W .005% FOIL

0

ZUP/NC404

ZUP/NC404

TDK-Lambda, Inc.

ZUP RS485 COMM. CABLE 25 PIN

0

C700

C700

Fluke Electronics

HARD CARRYING CASE (700 SERIES)

0

50-000040-01

50-000040-01

Versatile Power

BENCH RACK MOUNT KIT

100

BU-49-9

BU-49-9

Mueller Electric Co.

INSULATOR AUTO ANALYZER PVC WHT

183495

PACC-MS003

PACC-MS003

Teledyne LeCroy

LOW C FIXED TIP CARTRIDGE

11

72-143-0

72-143-0

NTE Electronics, Inc.

BLK INSULATOR FOR 72-136/137

0

VS-AVT-CABLE-02

VS-AVT-CABLE-02

Panduit Corporation

VERISAFE REPLACEMENT AVT SYSTEM

12307

4824

4824

Introspect Technology

PV1PSU PWR SUPPLY FOR PV1

1

779195-01

779195-01

NI

R37F-37M-1 37-PIN FEMALE TO MALE

12

VS-CKBB8-4

VS-CKBB8-4

Panduit Corporation

VERISAFE CONNECTION KIT FOR TAPP

512

AI-000443

AI-000443

Mueller Electric Co.

BU-118 TO BU-27 SS ROPE 17"

481595

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top