Accessories

Image Part Number Description / PDF Quantity Rfq
03S110-K21S3

03S110-K21S3

Rosenberger

PRECISION 3.5 CALIBRATION ADAPTO

0

PSU-5VDC-USB-US

PSU-5VDC-USB-US

Lascar Electronics

PWR SUPPLY 5VDC USB OUT

10

R3500-ELECTRODE

R3500-ELECTRODE

REED Instruments

PH ELECTRODE FOR R3500

11

QC-MPO-16/32-1P

QC-MPO-16/32-1P

Fluke Networks

QUICK CLEAN MPO 16/32 FIBER SGL

10

SSA3000XR-EMI

SSA3000XR-EMI

Siglent Technologies

EMI ACTIVATION LICENSE (SSA3000X

4

501T

501T

Tempo Communications

TRANSMITTER FOR 501

0

BU-62-2

BU-62-2

Mueller Electric Co.

INSULATOR FOR BU-60,61 SRS RED

284269157

69193

69193

Klein Tools

MM100 FUSE KIT

2

IC1

IC1

Tempo Communications

INDUCTIVE COUPLER

0

PACC-ZD009

PACC-ZD009

Teledyne LeCroy

MICRO SPRINGLOADED ZD DIFF PRB

0

18S12L-000D3

18S12L-000D3

Rosenberger

MINI SMP OPEN

0

T3SA3000-RLB

T3SA3000-RLB

Teledyne LeCroy

RETURN LOSS BRIDGE FOR T3SA SERI

1

BU-13-9

BU-13-9

Mueller Electric Co.

INSULATOR FOR BU-11 SERIES WHT

18308

AI-000500-60

AI-000500-60

Mueller Electric Co.

60" GROUND CABLE BU-21CPN

45

SDS2000XP-FLEXRAY

SDS2000XP-FLEXRAY

Siglent Technologies

FLEXRAY DECODING ACTIVATION LICE

4

MP1-MAGNET PROBE 1

MP1-MAGNET PROBE 1

Fluke Electronics

MAGNET PROBES FOR 4MM BANANA SET

0

DL-HCM-HITEMP

DL-HCM-HITEMP

Teledyne LeCroy

DL-HCM SERIES HIGH-TEMPERATURE S

0

SDS-5000X-16LA

SDS-5000X-16LA

Siglent Technologies

MSO/DIGITAL ACTIVATION LICENSE (

4

VDV999-067

VDV999-067

Klein Tools

TRACEALL LEADS

1

03S1AM-K20S3

03S1AM-K20S3

Rosenberger

PRECISION 3.50 CALIBRATION ADAPT

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top