Snap Action, Limit Switches

Image Part Number Description / PDF Quantity Rfq
D2SP0236R

D2SP0236R

Waldom Electronics

MINI BASIC SWITCH

1194

D3SH0014H

D3SH0014H

Waldom Electronics

ULTRA MINI SMT DETECTION SW

15538

VX5 0017G

VX5 0017G

Waldom Electronics

MINI BASIC SWITCH

66

D2FN1033B

D2FN1033B

Waldom Electronics

BASIC SWITCH

11

SSM 0040E

SSM 0040E

Waldom Electronics

BASIC SWITCH

8608

D2JW0003A

D2JW0003A

Waldom Electronics

AUTO SWITCHES IMERSIONPROOF BAS

500

D3VM1214R

D3VM1214R

Waldom Electronics

MINI BASIC SWITCH

205

SSM 0004R

SSM 0004R

Waldom Electronics

BASIC SWITCH

253

D3VM0455C

D3VM0455C

Waldom Electronics

MINI BASIC SWITCH

1049

D2HW2316R

D2HW2316R

Waldom Electronics

AUTO SWITCHES BASIC SWITCH

94

D2VW2233A

D2VW2233A

Waldom Electronics

AUTO SWITCHES MINI BASIC SWITCH

9

DB3C-A1LC

DB3C-A1LC

Waldom Electronics

SWITCH SNAP ACT SPDT 100MA 125V

40491

SSM 0052R

SSM 0052R

Waldom Electronics

BASIC SWITCH

500

D2FN1001D

D2FN1001D

Waldom Electronics

BASIC SWITCH

851

D449-R1MD-G2

D449-R1MD-G2

Waldom Electronics

SWITCH SNAP ACTION SPDT 10A 250V

2357

D3VM0734M

D3VM0734M

Waldom Electronics

MINI BASIC SWITCH

80

SS5M0002D

SS5M0002D

Waldom Electronics

BASIC SWITCH

1231

D3VM0699H

D3VM0699H

Waldom Electronics

SNAP ACTION SWITCH

200

D2VW2231E

D2VW2231E

Waldom Electronics

AUTO SWITCHES MINI BASIC SWITCH

4

D2MQ1013D

D2MQ1013D

Waldom Electronics

SWITCH

8

Snap Action, Limit Switches

1. Overview

Snap-action switches and limit switches are critical electromechanical components that enable precise control of electrical circuits through mechanical motion. Snap-action switches feature a rapid-acting contact mechanism that ensures quick response to positional changes, while limit switches specifically detect the presence or absence of objects at predefined positions. These devices are fundamental in automation systems, safety circuits, and equipment interlocking, providing reliable feedback for process control and machine protection.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Standard Snap-Action SwitchFast contact actuation, compact size, tactile feedbackAppliances, control panels
Heavy-Duty Limit SwitchMetal housing, high mechanical enduranceIndustrial machinery, conveyor systems
Sealed Snap SwitchIP67-rated enclosure, resistant to dust/moistureOutdoor equipment, washdown environments
Miniature Snap SwitchSub-10mm dimensions, low operating forceMedical devices, IoT sensors

3. Structure and Components

Typical construction includes: - Actuator Mechanism: Lever, plunger, or roller assembly for motion detection - Contact System: Silver alloy contacts with snap-action spring for rapid switching - Housing: Thermoplastic (UL94 V-0) or metal enclosure with mounting features - Terminal Options: Quick-connect terminals, PCB pins, or screw terminals - Environmental Seals: Optional EPDM gaskets or molded-in sealing lips

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current0.1-15ADetermines load capacity and contact lifespan
Operating Voltage12-600VAC/DCAffects insulation requirements and arcing resistance
Mechanical Life10 -10 operationsIndicates durability under non-load conditions
Electrical Life10 -10 operationsMeasures contact longevity under rated load
Actuation Force0.5-20NAffects sensitivity and mechanical interface design
Response Time1-10msCritical for high-speed automation applications

5. Application Fields

  • Industrial Automation: CNC machine tool positioning, robotic end-effectors
  • Building Systems: HVAC damper control, automatic door systems
  • Medical Equipment: Diagnostic analyzers, infusion pump occlusion detection
  • Consumer Electronics: Smart home devices, gaming console controllers
  • Transportation: Elevator door safety systems, railcar detection

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
OmronD4MC SeriesIP67 rating, 10 mechanical operations
TE ConnectivityMicro Switch TL SeriesUL-certified, 15A rating
ABBPLS SeriesAdjustable actuator, explosion-proof design
OMRONZ-15 Series0.1A low-current switching capability

7. Selection Guidelines

Key considerations include: - Environmental conditions (temperature range, presence of contaminants) - Actuation force requirements vs. mechanical interface limitations - Contact configuration (SPDT/DPDT) and circuit requirements - Certification needs (UL, CSA, CE marks) - Mounting constraints (panel cutout dimensions) Example: For an automatic door system, specify a sealed IP65 switch with 10A/250VAC rating and lever actuator to ensure reliable operation in dusty environments.

8. Industry Trends

Current development directions include: - Integration with IoT systems through embedded sensing and wireless communication - Miniaturization for wearable and portable device applications - Enhanced material science for extended lifespan in harsh environments - Development of hybrid switches combining snap-action with proximity sensing - Increased focus on RoHS-compliant and recyclable materials - Smart diagnostics capabilities with condition monitoring sensors