Current Sensors

Image Part Number Description / PDF Quantity Rfq
LA 150-TP

LA 150-TP

LEM USA, Inc.

SENSOR CURRENT HALL 150A AC/DC

0

AT 100 B5

AT 100 B5

LEM USA, Inc.

SENSOR CURRENT XFMR 100A AC

0

LXSR 6-NPS

LXSR 6-NPS

LEM USA, Inc.

SENSOR CURRENT HALL 6A UNIPOLAR

2

HO 60-P

HO 60-P

LEM USA, Inc.

SENSOR CURRENT HALL 60A AC/DC

0

HAL 100-S

HAL 100-S

LEM USA, Inc.

SENSOR CURRENT HALL 100A AC/DC

3

LKSR 50-NP

LKSR 50-NP

LEM USA, Inc.

SENSOR CURRENT HALL 50A UNIPOLAR

275

HAT 500-S

HAT 500-S

LEM USA, Inc.

SENSOR CURRENT HALL 500A AC/DC

0

LT 100-S/SP30

LT 100-S/SP30

LEM USA, Inc.

SENSOR CURRENT HALL 100A AC/DC

0

HLSR 50-PW-000

HLSR 50-PW-000

LEM USA, Inc.

DIGITAL OUTPUT OPEN LOOP 50A

392

HAW 10-P

HAW 10-P

LEM USA, Inc.

SENSOR CURRENT HALL 10A AC/DC

0

HY 20-P

HY 20-P

LEM USA, Inc.

SENSOR CURRENT HALL 20A AC/DC

0

HOYS 100-S-0100

HOYS 100-S-0100

LEM USA, Inc.

100 A OPEN LOOP BUS BAR MOUNT

35

HLSR 16-PW-000

HLSR 16-PW-000

LEM USA, Inc.

DIGITAL OUTPUT OPEN LOOP 16A

382

HAS 50-P

HAS 50-P

LEM USA, Inc.

SENSOR CURRENT HALL 50A AC/DC

0

HOYL 600-S-0100

HOYL 600-S-0100

LEM USA, Inc.

600A 5V OL BUS BAR MOUNT

0

HLSR 40-PW-000

HLSR 40-PW-000

LEM USA, Inc.

DIGITAL OUTPUT OPEN LOOP 40A

399

HAW 05-P

HAW 05-P

LEM USA, Inc.

SENSOR CURRENT HALL 5A AC/DC

0

HO 100-PW-0000

HO 100-PW-0000

LEM USA, Inc.

DIGITAL OUTPUT OL PCB MT 100A

84

HAX 1500-S

HAX 1500-S

LEM USA, Inc.

SENSOR CURRENT HALL 1500A AC/DC

0

LT 1005-S

LT 1005-S

LEM USA, Inc.

SENSOR CURRENT HALL 1000A AC/DC

0

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.

RFQ BOM Call Skype Email
Top