Current Sensors

Image Part Number Description / PDF Quantity Rfq
ACS758LCB-100B-PFF-T

ACS758LCB-100B-PFF-T

Allegro MicroSystems

SENSOR CURRENT HALL 100A AC/DC

0

HO 250-P

HO 250-P

LEM USA, Inc.

SENSOR CURRENT HALL 250A AC/DC

87

HAL 50-S

HAL 50-S

LEM USA, Inc.

SENSOR CURRENT HALL 50A AC/DC

0

AIMH040-800A-420B

AIMH040-800A-420B

Aim Dynamics

CURRENT SENSOR 800A 4-20MA

38

LF 2005-S

LF 2005-S

LEM USA, Inc.

SENSOR CURRENT HALL 2000A AC/DC

58

L03S400D15

L03S400D15

Tamura

SENSOR CURRENT HALL 400A AC/DC

196

ASI100

ASI100

Asentek

IND CURRENT TRANS 100A .02%

0

S22P025S05

S22P025S05

Tamura

SENSOR CURRENT HALL 25A AC/DC

0

LF 505-S

LF 505-S

LEM USA, Inc.

SENSOR CURRENT HALL 500A AC/DC

182

ACS724LLCTR-20AU-T

ACS724LLCTR-20AU-T

Allegro MicroSystems

SENSOR CURRENT HALL 20A DC

0

S27S300D15YM

S27S300D15YM

Tamura

SENSOR CURRENT HALL 300A AC/DC

79

HO 60-NP

HO 60-NP

LEM USA, Inc.

SENSOR CURRENT HALL 60A AC/DC

0

CTR05000

CTR05000

Red Lion

SENSOR CURRENT XFMR 10A, 20, 50A

0

ACS720KLATR-35AB-T

ACS720KLATR-35AB-T

Allegro MicroSystems

CURRENT SENSOR

0

SCT-0400-060

SCT-0400-060

Aim Dynamics

CURRENT SENSE MAGNALAB 60A:333MV

31

CQ3301

CQ3301

Asahi Kasei Microdevices / AKM Semiconductor

SENSOR CURRENT HALL 35A AC/DC

0

ASH100

ASH100

Asentek

HALL-REPLACEMENT TRANS 100A .05%

2

RCS-1800-2500

RCS-1800-2500

Aim Dynamics

CURRENT SENSE MAGNA 2500A:333MV

10

ASR3000

ASR3000

Asentek

LOW CURRENT TRANS 3A .2%

2

CR9321-PNP

CR9321-PNP

CR Magnetics, Inc.

SENSOR CURRENT SWITCH 100A PNP

537

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.

RFQ BOM Call Skype Email
Top