Current Sensors

Image Part Number Description / PDF Quantity Rfq
SCT-0400-001

SCT-0400-001

Aim Dynamics

CURRENT SENSE MAGNALAB 1A:333MV

54

CAS 50-NP

CAS 50-NP

LEM USA, Inc.

SENSOR CURRENT FLUX 50A AC/DC

314

F02P050S05

F02P050S05

Tamura

SENSOR CURRENT FLUX GATE 50A AC

0

TLI4971A120T5UE0001XUMA1

TLI4971A120T5UE0001XUMA1

IR (Infineon Technologies)

POSITION&CURRENT SENSORS

1477

MLX91220KDF-ABF-025-SP

MLX91220KDF-ABF-025-SP

Melexis

IC CURRENT SENSOR P&P 16SOIC

39

MNS2-9-IN-3P-150

MNS2-9-IN-3P-150

Monnit

ALTA IND 3 PHASE CURRENT 150A

0

LPSR 15-NP KIT

LPSR 15-NP KIT

LEM USA, Inc.

3 PIECE KIT SENSOR CURRENT HALL

4

CR4220-5

CR4220-5

CR Magnetics, Inc.

SENSOR CURRENT XFMR 5A AC

17

CR4110-100

CR4110-100

CR Magnetics, Inc.

SENSOR CURRENT XFMR 100A AC

0

ACS716KLATR-12CB-NL-T

ACS716KLATR-12CB-NL-T

Allegro MicroSystems

SENSOR CURRENT HALL 12.5A AC/DC

0

ACS37612LLUALU-015U5

ACS37612LLUALU-015U5

Allegro MicroSystems

STANDALONE CORELESS DIFFERENTIAL

353

MLX91221KDF-ABF-020-SP

MLX91221KDF-ABF-020-SP

Melexis

IC CURRENT SENSOR P&P 16SOIC

39

AT 50 B5

AT 50 B5

LEM USA, Inc.

SENSOR CURRENT XFMR 50A AC

0

AAV004-02E

AAV004-02E

NVE Corporation

IC GMR SENSOR 8-SOIC

0

CQ2063

CQ2063

Asahi Kasei Microdevices / AKM Semiconductor

SENSOR CURRENT HALL 50A AC/DC

0

20310500101

20310500101

HARTING

SENSOR CURRENT HALL 500A AC

13

MLX91220KDF-ABR-050-SP

MLX91220KDF-ABR-050-SP

Melexis

IC CURRENT SENSOR P&P 16SOIC

0

RCT-1800-500

RCT-1800-500

Aim Dynamics

CURRENT SENSE MAGNA 500A:333MV

46

MLX91206LDC-CAH-104-TU

MLX91206LDC-CAH-104-TU

Melexis

SENSOR CURRENT HALL 25MT AC/DC

0

ACS770LCB-100B-PFF-T

ACS770LCB-100B-PFF-T

Allegro MicroSystems

SENSOR CURRENT HALL 100A AC/DC

0

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.