Signal Relays, Up to 2 Amps

Image Part Number Description / PDF Quantity Rfq
3-1617543-0

3-1617543-0

TE Connectivity Aerospace Defense and Marine

JMGST-12L=M28776/7-004L

0

3-1617514-4

3-1617514-4

TE Connectivity Aerospace Defense and Marine

3SAT1331A2=M5757/13-114

0

PRMSCDG-26X

PRMSCDG-26X

TE Connectivity Aerospace Defense and Marine

PRMSCDG-26X=RELAY

0

JMSCD-5XM

JMSCD-5XM

TE Connectivity Aerospace Defense and Marine

JMSCD-5XM = M39016/16-033M

0

4-1617597-2

4-1617597-2

TE Connectivity Aerospace Defense and Marine

PR1MACD-6X=RELAY

0

1-1617024-0

1-1617024-0

TE Connectivity Aerospace Defense and Marine

HF1201D00 = HF 1/2 SIZE RELAY

0

JMGSCD-12PW

JMGSCD-12PW

TE Connectivity Aerospace Defense and Marine

JMGSCD-12PW = M39016/42-051P

0

HFW1201L01P

HFW1201L01P

TE Connectivity Aerospace Defense and Marine

HFW1201L01P = M39016/6-139P

0

1617148-9

1617148-9

TE Connectivity Aerospace Defense and Marine

JMGAPD-6M = M39016/18-026M

0

JMSC-5XL

JMSC-5XL

TE Connectivity Aerospace Defense and Marine

JMSC-5XL = M39016/11-033L

0

1-1617016-9

1-1617016-9

TE Connectivity Aerospace Defense and Marine

3SBK5132K1 = 2PDT FULL SIZE GR

0

1617035-4

1617035-4

TE Connectivity Aerospace Defense and Marine

HFW1501S24 = HFW 1/2 SIZE RELA

0

3SBH5004K5

3SBH5004K5

TE Connectivity Aerospace Defense and Marine

3SBH5004K5 = RELAY

0

9-1617598-3

9-1617598-3

TE Connectivity Aerospace Defense and Marine

PRMCST-26XW=RELAY

0

JMACDD-26XL

JMACDD-26XL

TE Connectivity Aerospace Defense and Marine

JMACDD-26XL = M39016/20-054L

0

2-1617541-9

2-1617541-9

TE Connectivity Aerospace Defense and Marine

J1MSPD-6XP=M39016/25-026P

0

9-1617540-7

9-1617540-7

TE Connectivity Aerospace Defense and Marine

J1MSCD-12XPS=M39016/25-043P

0

6-1617090-2

6-1617090-2

TE Connectivity Aerospace Defense and Marine

LS-9543 = LS RELAY

0

1617052-3

1617052-3

TE Connectivity Aerospace Defense and Marine

SF50111S01 = SF 5000 RELAY

0

1-1617011-9

1-1617011-9

TE Connectivity Aerospace Defense and Marine

3SAE2440A2 = 2PDT FULL SIZE S

0

Signal Relays, Up to 2 Amps

1. Overview

Signal relays with ratings up to 2 amps are electromechanical or solid-state switching devices designed to control low-power electrical circuits. These components enable signal transmission isolation, circuit amplification, or switching automation in modern electronic systems. Their compact size and precise control capabilities make them essential in automation, telecommunications, and precision instrumentation systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic RelaysMechanical switching via electromagnetic coil, standard form factorIndustrial control panels, HVAC systems
Solid-State RelaysNo moving parts, zero-crossing switching, fast responseTemperature control systems, LED lighting
Reed RelaysHermetically sealed contacts, high-speed operationTelecom switching, test equipment
Time Delay RelaysProgrammable switching intervalsMachinery automation, motor starters
High-Frequency RelaysDesigned for RF/microwave signal pathsWireless infrastructure, radar systems

3. Structure and Components

Typical construction includes:

  • Coil assembly (copper winding on bobbin)
  • Contact system (fixed and movable contacts)
  • Insulation housing (flame-retardant polymer)
  • Magnetic circuit (iron core and yoke)
  • Terminal system (PCB pins or screw terminals)

Advanced models incorporate EMI suppression circuits and LED status indicators.

4. Key Technical Parameters

ParameterTypical ValueImportance
Rated Current1-2 A resistiveDetermines load capacity
Coil Voltage5-48 VDC nominalDictates control circuit design
Contact Resistance<50 m Impacts signal integrity
Insulation Resistance>100 M Safety isolation performance
Mechanical Life10-100 million operationsDurability indicator
Switching Speed5-15 ms (EMR), <1 ms (SSR)System response time

5. Application Fields

  • Industrial automation (PLCs, sensor interfaces)
  • Telecom infrastructure (signal routing switches)
  • Medical equipment (diagnostic device controls)
  • Smart home systems (HVAC thermostats)
  • Test & measurement (ATE machine interfaces)

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
OmronG5LE-14-DC55 mm spacing, 2 A rating
Phoenix ContactPSR-SCP-24UCPlug-in design, LED indicators
TE ConnectivityRTX-S-DC5VAutomotive qualified
Siemens3RT2025Modular mounting system

7. Selection Recommendations

Key considerations:

  • Load type (resistive/inductive)
  • Environmental conditions (temperature/humidity)
  • Required make/break cycles
  • Regulatory certifications (UL/CSA/IEC)
  • PCB footprint constraints

Example: For medical equipment, select RoHS-compliant reed relays with 1.5 A rating and reinforced insulation.

8. Industry Trends

Current developments include:

  • Transition to surface-mount solid-state alternatives
  • Integration with IoT-enabled monitoring systems
  • Nanocoating for harsh environment protection
  • Increased adoption of 1 Form C contacts
  • Miniaturization (sub-10 mm package development)

Market forecasts predict 5.2% CAGR through 2027 driven by industrial automation growth.

RFQ BOM Call Skype Email
Top