Safety Relays

Image Part Number Description / PDF Quantity Rfq
EM-T-7A

EM-T-7A

Banner Engineering

SAFETY EXTENSION MODULE

11

UM-FA-9A

UM-FA-9A

Banner Engineering

SAFETY RELAY MODULE

15

ES-UA-5A

ES-UA-5A

Banner Engineering

SAFETY MODULE E-STOP/INTERLOCK

26

AT-FM-10K

AT-FM-10K

Banner Engineering

SAFETY MODULE TWO-HAND CONTROL

7

MMD-TA-12B

MMD-TA-12B

Banner Engineering

SAFETY RELAY MUTING MODULE

1

EM-F-7G

EM-F-7G

Banner Engineering

SAFETY EXTENSION MODULE

3

EM-FD-7G3

EM-FD-7G3

Banner Engineering

SAFETY EXTENSION MODULE INPUTS:

3

UM-FA-11A

UM-FA-11A

Banner Engineering

SAFETY RELAY MODULE

8

SR-IM-9A

SR-IM-9A

Banner Engineering

SAFETY RELAY MOD LIGHT CURTAIN

12

ES-FA-6G

ES-FA-6G

Banner Engineering

SAFETY MODULE E-STOP/INTERLOCK

5

ES-VA-5A

ES-VA-5A

Banner Engineering

SAFETY MODULE E-STOP/INTERLOCK

5

ES-FA-9AA

ES-FA-9AA

Banner Engineering

SAFETY MODULE E-STOP/INTERLOCK

27

GM-FA-10J

GM-FA-10J

Banner Engineering

SAFETY MODULE FOR INTERLOCK

18

AT-GM-13A

AT-GM-13A

Banner Engineering

SAFETY MODULE TWO-HAND CONTROL

10

SR-IM-11A

SR-IM-11A

Banner Engineering

SAFETY RELAY MOD LIGHT CURTAIN

1

ES-FA-11AA

ES-FA-11AA

Banner Engineering

SAFETY MODULE E-STOP/INTERLOCK

7

ES-FL-2A

ES-FL-2A

Banner Engineering

SAFETY MODULE E-STOP/INTERLOCK

0

IM-T-9A

IM-T-9A

Banner Engineering

SAFETY MOD LIGHT CURAIN W/EDM

3

MMD-TA-11B

MMD-TA-11B

Banner Engineering

SAFETY RELAY MUTING MODULE

0

IM-T-11A

IM-T-11A

Banner Engineering

SAFETY MOD LIGHT CURAIN W/EDM

8

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities