Safety Relays

Image Part Number Description / PDF Quantity Rfq
V23047A1005A501

V23047A1005A501

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY DPDT 6A 5V

1306

MMD-TA-12B

MMD-TA-12B

Banner Engineering

SAFETY RELAY MUTING MODULE

1

UE48-3OS3D2

UE48-3OS3D2

SICK

RELAY SAFETY 3PST 6A 24V

6

1104985

1104985

Phoenix Contact

SAFE EXTENSION MODULE WITH 4 SAF

7

G7S-3A3B-E DC24

G7S-3A3B-E DC24

Omron Automation & Safety Services

RELAY SAFETY 6PST 10A 24V

32

SFS5-L-DC12V-D

SFS5-L-DC12V-D

Panasonic

RELAY SAFETY 6PST 6A 12V

0

1104972

1104972

Phoenix Contact

CONFIGURABLE SAFETY MODULE (BASI

5

2700524

2700524

Phoenix Contact

RELAY SAFETY 3PST 6A 24V

0

RLY3-OSSD2

RLY3-OSSD2

SICK

RELAY SAFETY DPST 6A 24V

2

UE43-3MF2A3

UE43-3MF2A3

SICK

RELAY SAFETY 4PST 6A 230V

4

2981402

2981402

Phoenix Contact

RELAY SAFETY 7PST 6A 120V

1

SFY3-DC21V

SFY3-DC21V

Panasonic

RELAY SAFETY 4PST 6A 21V

0

1104986

1104986

Phoenix Contact

SAFE EXTENSION MODULE WITH 4 SAF

23

SFS2-DC48V

SFS2-DC48V

Panasonic

RELAY SAFETY 4PST 6A 48V

0

V23050-A1024-A551

V23050-A1024-A551

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY 6PST 8A 24V

0

G1502S

G1502S

ifm Efector

SAFETY RELAY

0

SFS5-L-DC24V-D

SFS5-L-DC24V-D

Panasonic

RELAY SAFETY 6PST 6A 24V

0

1104989

1104989

Phoenix Contact

SAFE EXTENSION MODULE FOR MONITO

23

ASFM0055S

ASFM0055S

Panasonic

RELAY SAFETY DPST NO/NC 6A/3A 5V

0

V23050A1021A542

V23050A1021A542

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY 6PST 8A 21V

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities
RFQ BOM Call Skype Email