Safety Relays

Image Part Number Description / PDF Quantity Rfq
56.OA01.0631C

56.OA01.0631C

Altech Corporation

OA5601 6V 3NO/1NC AGSN02+02UMAU

0

56.OA42.4811N

56.OA42.4811N

Altech Corporation

OA5642 48VDC1NO/1NC CONTACTS AGN

0

56.OA12.1224N

56.OA12.1224N

Altech Corporation

OA561212V 2NO/4NC AGNI10+2UMAU I

0

1SIP51224

1SIP51224

Altech Corporation

RELAY SAFETY 6PST 16A 24V

0

56.OA44.1222N

56.OA44.1222N

Altech Corporation

OA5644 12VDC2NO/2NC CONTACTS AGN

0

56.OA02.2424N

56.OA02.2424N

Altech Corporation

OA560224V 2NO/4NC AGNI10+2UMAU I

0

56.OA03.2462C

56.OA03.2462C

Altech Corporation

OA560324V 6NO/2NC AGSN02+02UMAU

30

56.OA44.2431S

56.OA44.2431S

Altech Corporation

OA5644 24VDC3NO/1NC CONTACTS AGN

0

56.OA43.6021C

56.OA43.6021C

Altech Corporation

OA5643 48VDC2NO/1NC CONTACTS AGS

0

56.OA02.2424S

56.OA02.2424S

Altech Corporation

OA560224V 2NO/4NC AGNI10+5UMAU I

0

56.OA03.0653C

56.OA03.0653C

Altech Corporation

OA5603 6V 5NO/3NC AGSN02+02UMAU

0

56.OA44.2131N

56.OA44.2131N

Altech Corporation

OA5644 21VDC3NO/1NC CONTACTS AGN

0

156.OA02.2424C

156.OA02.2424C

Altech Corporation

RELAY SAFETY 6PST 10A 24V

0

56.OA03.2453N

56.OA03.2453N

Altech Corporation

OA560324V 5NO/3NC AGNI10+2UMAU I

0

456.OA11.2422C

456.OA11.2422C

Altech Corporation

SAFETY MODULE 4 CH 4P8A 24V 2NO/

0

2901428

2901428

Phoenix Contact

RELAY SAFETY

0

256.OA11.1231C

256.OA11.1231C

Altech Corporation

2 CHANNEL MODULE 4P8A 12V 3NO/1N

0

156.OA02.1233C

156.OA02.1233C

Altech Corporation

RELAY SAFETY 6PST 10A 12V

0

56.OW70.1122N

56.OW70.1122N

Altech Corporation

OW5670110VDC2NO/2NC CONTACTS AGN

0

4-1415542-5

4-1415542-5

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities
RFQ BOM Call Skype Email