Safety Relays

Image Part Number Description / PDF Quantity Rfq
56.OA02.1142N

56.OA02.1142N

Altech Corporation

OA5602110V4NO/2NC AGNI10+2UMAU I

0

8949.3C/P

8949.3C/P

Altech Corporation

SAFETY RELAY12VDC DPDT CONTACT C

0

56.OW70.0631N

56.OW70.0631N

Altech Corporation

OW5670 6VDC3NO/1NC CONTACTS AGNI

0

56.OA69.1200S

56.OA69.1200S

Altech Corporation

OA566912V 2CO AGNI10+5UMAU IP40

0

56.OA43.4821S

56.OA43.4821S

Altech Corporation

OA5643 48VDC2NO/1NC CONTACTS AGN

0

8963.2S

8963.2S

Altech Corporation

RM2E16 16 SAFETY RELAY MODULE 12

0

56.OW69.2011N

56.OW69.2011N

Altech Corporation

OW566920V 1NO/1NC AGNI10+2UMAU I

0

8951.2N

8951.2N

Altech Corporation

SAFETY RELAY 1CH DPDT 24VDC CONT

0

256.OA02.2442C

256.OA02.2442C

Altech Corporation

2 CHANNEL MODULE 6P10A 24V 4NO/2

0

56.OW70.1231S

56.OW70.1231S

Altech Corporation

OW5670 12VDC3NO/1NC CONTACTS AGN

0

56.OA44.0622N

56.OA44.0622N

Altech Corporation

OA5644 6VDC2NO/2NC CONTACTS AGNI

0

G9SB-301-D AC/DC24

G9SB-301-D AC/DC24

Omron Automation & Safety Services

G9SB-301-D AC/DC24

0

56.OA43.1121C

56.OA43.1121C

Altech Corporation

OA5643 110VDC2NO/1NC CONTACT AGS

0

56.OA02.0633N

56.OA02.0633N

Altech Corporation

OA5602 6V 3NO/3NC AGNI10+2UMAU I

0

56.OW70.2422S

56.OW70.2422S

Altech Corporation

OW5670 24VDC2NO/2NC CONTACTS AGN

0

56.OA12.0642N

56.OA12.0642N

Altech Corporation

OA5612 6V 4NO/2NC AGNI10+2UMAU I

0

6-1415395-1

6-1415395-1

TE Connectivity Potter & Brumfield Relays

RELAY GEN PURPOSE 6PST 8A 12V

0

8972.2S

8972.2S

Altech Corporation

RM2G16 16CHAN SAFETY RELAY MODUL

0

UE12-2FG2D0

UE12-2FG2D0

SICK

RELAY SAFETY 3PST 6A 24V

0

8956.3C

8956.3C

Altech Corporation

RM2G8 SAFETY RELAY 1 8CHANNEL 24

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities