Safety Relays

Image Part Number Description / PDF Quantity Rfq
7S.14.9.012.4220

7S.14.9.012.4220

Finder Relays, Inc.

SFTY RLY GUIDE 2NO+2NC 6A 12VDC

0

56.OA11.1222S

56.OA11.1222S

Altech Corporation

OA561112V 2NO/2NC AGNI10+5UMAU I

0

G7SA-4A2B DC110

G7SA-4A2B DC110

Omron Automation & Safety Services

RELAY SAFETY 6PST 6A 110V

0

156.OA01.2422C

156.OA01.2422C

Altech Corporation

RELAY SAFETY 4PST 10A 24V

0

ISS-105-ISO-3

ISS-105-ISO-3

Wickmann / Littelfuse

3CH INTRINSICALLY-SAFE ONLY

1

56.OA43.1121S

56.OA43.1121S

Altech Corporation

OA5643 110VDC2NO/1NC CONTACT AGN

0

1393260-9

1393260-9

Waldom Electronics

SR6B4040 - V23050-A1040-A542

78

56.OW69.2411S

56.OW69.2411S

Altech Corporation

OW566924V 1NO/1NC AGNI10+5UMAU I

0

56.OA42.2111S

56.OA42.2111S

Altech Corporation

OA5642 21VDC1NO/1NC CONTACTS AGN

0

7S.34.8.120.4310

7S.34.8.120.4310

Finder Relays, Inc.

SFTY RLY GUIDE 3NO+1NC 6A 120VAC

0

256.OA12.2442C

256.OA12.2442C

Altech Corporation

2 CHANNEL MODULE 6P 8A 24V 4NO/2

0

156.OA01.24

156.OA01.24

Altech Corporation

RELAY SAFETY 10A 24V

0

56.OA70.2422C

56.OA70.2422C

Altech Corporation

OA567024VDC2NO/2NC CONTACTS AGSN

0

8956.2N

8956.2N

Altech Corporation

RM2G4 4 CHANNEL SAFETY RELAY MOD

0

7S.14.8.230.4310

7S.14.8.230.4310

Finder Relays, Inc.

SFTY RLY GUIDE 3NO+1NC 6A 230VAC

0

56.OA03.0626C

56.OA03.0626C

Altech Corporation

OA5603 6V 2NO/6NC AGSN02+02UMAU

0

56.OA12.2442S

56.OA12.2442S

Altech Corporation

OA561224V 4NO/2NC AGNI10+5UMAU I

20

56.OA70.0622N

56.OA70.0622N

Altech Corporation

OA5670 6VDC 2NO/2NC CONTACTS AGN

0

56.OA43.4821N

56.OA43.4821N

Altech Corporation

OA5643 48VDC2NO/1NC CONTACTS AGN

0

56.OA03.0671C

56.OA03.0671C

Altech Corporation

OA5603 6V 7NO/1NC AGSN02+02UMAU

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities
RFQ BOM Call Skype Email
Top