I/O Relay Modules

Image Part Number Description / PDF Quantity Rfq
X4IAC15

X4IAC15

Sensata Technologies – Crydom

AC INPUT MODULE 120V

0

DMP6101A

DMP6101A

Sensata Technologies – Crydom

DC INPUT MODULE 24V

0

X4ODC5A

X4ODC5A

Sensata Technologies – Crydom

DC OUTPUT MODULE 1A

0

X4IAC15A

X4IAC15A

Sensata Technologies – Crydom

AC INPUT MODULE 240V

0

X4IDC24

X4IDC24

Sensata Technologies – Crydom

DC INPUT MODULE 24V

0

X4OAC15

X4OAC15

Sensata Technologies – Crydom

AC OUTPUT MODULE 3A

0

IDC15D

IDC15D

Sensata Technologies – Crydom

DC INPUT MODULE 24V

0

6201A

6201A

Sensata Technologies – Crydom

AC INPUT MODULE 120V

0

6101

6101

Sensata Technologies – Crydom

DC INPUT MODULE 24V

0

X4ODC15

X4ODC15

Sensata Technologies – Crydom

DC OUTPUT MODULE 3A

0

X4IDC5D

X4IDC5D

Sensata Technologies – Crydom

DC INPUT MODULE 24V

0

6232

6232

Sensata Technologies – Crydom

AC INPUT MODULE 240V

0

X4IDC15D

X4IDC15D

Sensata Technologies – Crydom

DC INPUT MODULE 24V

0

X4IAC24

X4IAC24

Sensata Technologies – Crydom

AC INPUT MODULE 120V

0

6202A

6202A

Sensata Technologies – Crydom

AC INPUT MODULE 240V

0

M-IDC15

M-IDC15

Sensata Technologies – Crydom

DC INPUT MODULE 24V

0

X4OAC24A

X4OAC24A

Sensata Technologies – Crydom

AC OUTPUT MODULE 3A

0

ODC5AQ

ODC5AQ

Sensata Technologies – Crydom

DC OUTPUT MODULE 1A

0

X4ODC5R

X4ODC5R

Sensata Technologies – Crydom

DC OUTPUT MODULE 1A

0

IAC15A

IAC15A

Sensata Technologies – Crydom

AC INPUT MODULE 240V

0

I/O Relay Modules

1. Overview

I/O Relay Modules (Input/Output Relay Modules) are electronic devices that enable signal conversion and electrical isolation between control systems and external equipment. They act as intermediaries to control high-power circuits using low-power signals, playing a critical role in automation systems, industrial machinery, and smart infrastructure. These modules ensure safe and reliable switching operations in applications ranging from factory automation to renewable energy systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic RelaysMechanical switching via electromagnetic coils, high current capacityIndustrial motor control, HVAC systems
Solid-State Relays (SSR)No moving parts, fast switching, low EMITemperature control systems, semiconductor equipment
Hybrid RelaysCombines electromagnetic and solid-state advantagesPrecision manufacturing, aerospace systems
Programmable RelaysUser-configurable logic functionsCustom automation systems, R&D equipment
Smart RelaysIntegrated sensors, IoT connectivity, self-diagnosisSmart grids, predictive maintenance systems

3. Structure and Components

A typical I/O Relay Module consists of:

  • Housing: Flame-retardant polymer casing (UL 94 V-0 rated)
  • Contact System: Silver alloy for low resistance (AgSnO typical)
  • Coil Assembly: Copper winding with thermal class F insulation
  • Drive Circuitry: Transistor-based drivers for DC types or zero-crossing detection for AC
  • Isolation Layer: Reinforced insulation barrier (2500 Vrms basic insulation)

4. Key Technical Specifications

ParameterSignificanceTypical Range
Rated VoltageDetermines application circuit compatibility5VDC-250VAC
Current RatingAffects power handling capability1A-100A
Switching SpeedCritical for real-time control systems0.5ms-20ms
Electrical LifeDirectly impacts maintenance intervals10 - 10 operations
Insulation ResistanceEnsures safety isolation>100M @ 500VDC

5. Application Areas

  • Industrial Automation: PLC systems, assembly line robots
  • Energy Systems: Smart grid controllers, solar inverters
  • Transportation: Railway signaling, EV charging stations
  • Medical Equipment: Diagnostic imaging systems, infusion pumps

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
OmronMY2N-J30A rating, LED status indicator
SiemensSIMATIC ET 200PROFINET interface, hot-swappable
Schneider ElectricZelio SR2Programmable, LCD display
ABBAF250-30LEnergy-efficient coil, 125kHz switching
Phoenix ContactPSR-SCP-24DC-CTSafe separation, configurable delay

7. Selection Recommendations

Key considerations include:

  • Match voltage/current ratings with load requirements (125% safety margin recommended)
  • Environmental factors: operating temperature (-40 C to +85 C typical)
  • Mounting type: PCB, DIN rail, or panel mount
  • Communication protocol compatibility (Modbus, EtherCAT, etc.)
  • Failure Mode Analysis: Choose failsafe configuration per application needs

8. Industry Trends

Emerging developments include:

  • Integration with IIoT protocols (OPC UA, MQTT)
  • Miniaturization: 30% size reduction in 2023 models
  • Energy efficiency improvements: >85% coil power reduction
  • AI-enabled predictive maintenance features
  • Increased adoption of wide bandgap semiconductors in SSRs

Application Case Study

A automotive manufacturing plant implemented Omron MY4NJ relays in robotic welding systems, achieving:

  • 40% reduction in switching-related downtime
  • 25% energy savings through optimized coil drive
  • Integration with existing PROFINET network
RFQ BOM Call Skype Email