Contactors (Electromechanical)

Image Part Number Description / PDF Quantity Rfq
CGMS-6A-240-01

CGMS-6A-240-01

Carlo Gavazzi

RLY CONT AC COIL 1 NC AUX

0

CC32/4SA480-60HZ

CC32/4SA480-60HZ

Carlo Gavazzi

RLY CONT 4P 480V 60HZ NO AUX

0

CC12SD12

CC12SD12

Carlo Gavazzi

RLY CONT 3P 12V DC 1NO/1NC

0

CC800/4SAD200

CC800/4SAD200

Carlo Gavazzi

RLY CONT 4P 200VACDC 2NO/2NC

0

CC85/4SA110

CC85/4SA110

Carlo Gavazzi

RLY CONT 4P 110V 50/60HZ NO AUX

0

CC18SA220

CC18SA220

Carlo Gavazzi

RLY CONT 3P 220V 50/60HZ 1NO/1NC

0

CC40/4SA600-60HZ

CC40/4SA600-60HZ

Carlo Gavazzi

RLY CONT 4P 600V 60HZ NO AUX

0

CC32SA208-60HZ

CC32SA208-60HZ

Carlo Gavazzi

RLY CONT 3P 208V 60HZ 2NO/2NC

0

CC130LA110

CC130LA110

Carlo Gavazzi

3P CONT L 110V50/60HZ 2NO2NC

5

CGMS-12D-24S-10

CGMS-12D-24S-10

Carlo Gavazzi

CONTACTOR DC COIL 1NO AUX

8

CGMS-6D-24S-01

CGMS-6D-24S-01

Carlo Gavazzi

RLY CONT DC COIL 1NC AUX

0

CGMS-9A-220-10

CGMS-9A-220-10

Carlo Gavazzi

CONTACTOR AC COIL 1NO AUX

12

CC65LA480-60HZ

CC65LA480-60HZ

Carlo Gavazzi

RLY CONT 3P 480V 60HZ 2NO/2NC

0

CC22SA600-60HZ

CC22SA600-60HZ

Carlo Gavazzi

RLY CONT 3P 600V 60HZ 1NO/1NC

0

CC18/4SA110

CC18/4SA110

Carlo Gavazzi

RLY CONT 4P 110V 50/60HZ NO AUX

0

CC12/4SA208-60HZ

CC12/4SA208-60HZ

Carlo Gavazzi

RLY CONT 4P 208V 60HZ NO AUX

0

CC130/4SAD24

CC130/4SAD24

Carlo Gavazzi

RLY CONT 4P 24VACDC 2NO/2NC

0

CC50SA480-60HZ

CC50SA480-60HZ

Carlo Gavazzi

RLY CONT 3P 480V 60HZ 2NO/2NC

0

CC630SAD100

CC630SAD100

Carlo Gavazzi

3P CONT S 100 VAC/DC 2NO2NC

0

CGMS-6A-240-10

CGMS-6A-240-10

Carlo Gavazzi

RLY CONT AC COIL 1NO AUX

0

Contactors (Electromechanical)

1. Overview

Electromechanical contactors are electrically controlled switching devices designed to handle high-current loads. They operate through electromagnetic actuation to open or close contacts, enabling remote control of electrical circuits. These components are critical in industrial automation, power distribution, and motor control systems, offering reliable and scalable solutions for managing electrical loads ranging from kilowatts to megawatts.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
AC ContactorsDesigned for alternating current loads with arc suppression featuresMotor starters, HVAC systems
DC ContactorsOptimized for direct current circuits with magnetic blowout arcsElectric vehicle charging, battery systems
Heavy-Duty ContactorsHigh inrush current tolerance with reinforced contactsIndustrial furnaces, large compressors
Vacuum ContactorsUse vacuum as arc-quenching medium for high-voltage applicationsPower generation systems, traction equipment

3. Structure and Components

Typical construction includes:

  • Electromagnetic actuator (coil and iron core)
  • Main contacts (silver alloy for conductivity)
  • Auxiliary contacts (for control circuits)
  • Arc suppression system (grids or vacuum chambers)
  • Mechanical linkage assembly

4. Key Technical Parameters

ParameterSignificance
Rated operational current (Ie)Determines maximum load capacity
Rated voltage (Ue)Defines operating voltage range
Coil power consumptionAffects control circuit design
Mechanical life (cycles)Indicates durability without maintenance
Short-circuit withstandSafety margin for fault conditions

5. Application Fields

Primary industries include:

  • Industrial automation (motor control centers)
  • Power generation and distribution systems
  • Building HVAC equipment
  • Transportation infrastructure (traction systems)
  • Agricultural machinery (irrigation pumps)

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
Schneider ElectricTeSys D Green Contactors
Siemens3RT12xx series
ABBAF110-30LX vacuum contactor
OmronMY22S DC contactor

7. Selection Guidelines

Key considerations:

  • Load type (resistive/inductive) and inrush current
  • Environmental conditions (temperature, vibration)
  • Control voltage compatibility
  • Mounting orientation and space constraints
  • Certification requirements (IEC 61439, UL 508)
Example: For 400A motor control in a foundry, select a heavy-duty contactor with IP54 rating and class F insulation.

8. Industry Trends

Emerging developments:

  • Integration with IoT-enabled monitoring systems
  • Nano-coating technologies for harsh environments
  • Miniaturization through advanced arc suppression
  • Hybrid designs combining solid-state and electromechanical features
  • Eco-friendly materials reducing rare metal dependency

RFQ BOM Call Skype Email
Top