Accessories

Image Part Number Description / PDF Quantity Rfq
GT32S8A

GT32S8A

Carlo Gavazzi

TOR SCREW 32A 5-8A

3

RCK2-100-1

RCK2-100-1

Carlo Gavazzi

RK CABLE 2 X 0.14MM 100CM 1 CON

5

GUR02

GUR02

Carlo Gavazzi

MECH INTERLOCK ONLY 9-95A

6

RHS301F115C

RHS301F115C

Carlo Gavazzi

SSR RHS301 & 115V FAN ASSEMBLY

10

GT95L100A

GT95L100A

Carlo Gavazzi

TOR LUG 95A 80-100A

5

GT95S50A

GT95S50A

Carlo Gavazzi

TOR SCREW 95A 34-50A

5

GUW63

GUW63

Carlo Gavazzi

LINKS FOR REV CONT 63A

6

GT95L95A

GT95L95A

Carlo Gavazzi

TOR LUG 95A 70-95A

4

CGE22-3PR-22AN

CGE22-3PR-22AN

Carlo Gavazzi

CC SSOLR 3PR 22A 4.4-22A

5

GT32S32A

GT32S32A

Carlo Gavazzi

TOR SCREW 32A 22-32A

3

GT95S22A

GT95S22A

Carlo Gavazzi

TOR SCREW 95A 16-22A

5

GUA4-40

GUA4-40

Carlo Gavazzi

FRONT AUX 4NO CC9-185A

36

AI-800

AI-800

Carlo Gavazzi

INS BARRIER 600-800A

25

GUA4-13

GUA4-13

Carlo Gavazzi

FRONT AUX 1NO3NC CC9-185A

10

AX-2MS-20

AX-2MS-20

Carlo Gavazzi

FRNT AUX 2NO MINI SC

10

CGT-12M-0.25

CGT-12M-0.25

Carlo Gavazzi

TOR 12M 0.16-0.25

10

GT95S100A

GT95S100A

Carlo Gavazzi

TOR SCREW 95A 80-100A

5

GT32S0.16A

GT32S0.16A

Carlo Gavazzi

TOR SCREW 32A 0.1-0.16A

5

ZRMMOV24

ZRMMOV24

Carlo Gavazzi

AUX MOD ZRM SCKT MOV 24 VAC/VDC

20

GT95L25A

GT95L25A

Carlo Gavazzi

TOR LUG 95A 18-25A

5

Accessories

1. Overview

Relays Accessories are components designed to enhance the functionality, protection, and integration of electromagnetic relays in electrical systems. These accessories include mechanical supports, protective enclosures, contact modules, and signal interfaces. In modern technology, they play a critical role in ensuring reliability, safety, and adaptability of relay-based control systems across industries such as automation, energy, and transportation.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Protective CoversDust/waterproof enclosures (IP65-IP68), corrosion resistanceOutdoor power distribution cabinets
Mounting BasesQuick-install brackets, DIN rail compatibilityIndustrial control panels
Contact ModulesMulti-pole expansion, arc suppression designHigh-current motor controllers
Drive ModulesDC/AC voltage conversion, coil suppression circuitsPLC output stage amplification
Signal ConvertersVoltage/frequency isolation, optocoupler integrationRailway signaling systems

3. Structure and Composition

A typical relay accessory combines mechanical and electrical components:

  • Mechanical Structure: Injection-molded thermoplastic housing (e.g., PA66), metal mounting brackets, vibration-damping gaskets
  • Electrical Components: Silver-alloy contact plates, PCB-mounted transient voltage suppressors, thermal insulating layers
  • Interface Design: Standardized pin layouts (e.g., Eurocard 160x100mm), screwless terminal blocks (0.2-4mm wire compatibility)

4. Key Technical Specifications

ParameterValue RangeImportance
Insulation Resistance100M -10G Ensures dielectric safety
Rated Voltage12VDC-600VACDetermines application scope
Contact Resistance5-50m Affects power efficiency
Operating Temperature-40 C to +125 CEnvironmental adaptability
IP RatingIP20-IP69KProtection level selection
Electrical Life10,000-100,000 cyclesSystem longevity

5. Application Fields

  • Industrial Automation: PLC control cabinets, CNC machine relays
  • Power Systems: Transformer protection relays, grid monitoring equipment
  • Transportation: Train control systems, EV battery management
  • Consumer Electronics: Smart home relay modules, washing machine controllers
  • Medical Equipment: Patient monitoring systems, MRI machine relays

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
OmronMY2N-SR-DC12VHigh-vibration resistance, LED status indicator
Schneider ElectricRXM4ABBDModular design, thermal overload protection
Siemens3RT1025-1AP00Plug-in terminal blocks, 3-phase control
PanasonicJS1-12VDCMiniature size (15.7x38mm), low power consumption
TE ConnectivityRT114112Automotive-grade, AEC-Q100 certified

7. Selection Guidelines

Key considerations for selection include:

  • Environmental Conditions: Temperature extremes, humidity, and vibration levels
  • Load Requirements: Voltage/current ratings with 20% safety margin
  • Installation Method: PCB mount, panel mount, or DIN rail compatibility
  • Reliability Needs: MTBF (Mean Time Between Failures) >100,000 hours
  • System Compatibility: Matching coil voltage and contact configuration
  • Cost-Performance Ratio: Balancing durability and budget constraints

8. Industry Development Trends

Key trends shaping the future of relay accessories include:

  • Smart Integration: IoT-enabled accessories with embedded sensors for condition monitoring
  • Miniaturization: 30% size reduction achieved through advanced materials (e.g., LCP plastics)
  • Environmental Compliance: RoHS/REACH-compliant coatings and halogen-free materials
  • Modular Design: Interchangeable units for rapid system reconfiguration
  • High-Reliability Applications: Growth in aerospace and EV charging station accessories
  • Wireless Connectivity: Bluetooth-enabled relay modules for remote control systems
RFQ BOM Call Skype Email
Top