Panel Indicators, Pilot Lights

Image Part Number Description / PDF Quantity Rfq
L295000NAC

L295000NAC

Bulgin

LAMP PNL MNT

1976

LH677B

LH677B

Bulgin

LAMP HOLDER 12V BLUE

0

NL276H2A

NL276H2A

Bulgin

INDICATOR LIGHT NEON 110V AMBER

0

LH677A

LH677A

Bulgin

LAMP HOLDER 12V AMBER

0

C0430ATNAC

C0430ATNAC

Bulgin

LAMP PNL MNT

1494

FL67C7R

FL67C7R

Bulgin

LAMP INCANDESCENT 12V

0

LE276C3602

LE276C3602

Bulgin

INDICATOR LIGHT 12V LED GREEN

0

LH1037OAWL37007

LH1037OAWL37007

Bulgin

LED PANEL INDICATOR RED 14V

0

H8630FBBA3

H8630FBBA3

Bulgin

INDICATOR LIGHT 230V AMBER

0

NL277SWL2A

NL277SWL2A

Bulgin

INDICATOR LIGHT NEON 110V AMBER

0

LH1037OA37007

LH1037OA37007

Bulgin

LED PANEL INDICATOR RED 14V

0

NL589WL3A

NL589WL3A

Bulgin

INDICATOR LIGHT NEON 230V AMBER

0

FL2951WL7R

FL2951WL7R

Bulgin

INCAND PANEL INDICATOR RED 12V

0

LH1048BWL3602

LH1048BWL3602

Bulgin

INDICATOR LIGHT

0

FL245CWL7G

FL245CWL7G

Bulgin

INCAND PANEL INDICATOR GRN 12V

0

C430AABR3

C430AABR3

Bulgin

INDICATOR LIGHT 230V RED

0

DX0505/YL/00

DX0505/YL/00

Bulgin

VANDAL RESISTANT LED PMI YELLOW

0

NL276C3G

NL276C3G

Bulgin

INDICATOR 250V GREEN

0

DX0506/RD/24

DX0506/RD/24

Bulgin

VANDAL RESISTANT LED PMI RED

0

NL589H3R

NL589H3R

Bulgin

INDICATOR LIGHT NEON 230V RED

0

Panel Indicators, Pilot Lights

1. Overview

Panel indicators and pilot lights are optoelectronic devices that provide visual status feedback in electrical and electronic systems. These components convert electrical signals into light outputs, enabling operators to monitor equipment conditions at a glance. Their importance spans across industrial automation, consumer electronics, transportation, and medical devices, where reliable visual indication ensures operational safety, efficiency, and user interaction.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
LED Panel IndicatorsLow power consumption, long lifespan, instant responseIndustrial control panels, HVAC systems
Lamp-based Pilot LightsHigh brightness, compatibility with AC/DC circuitsMachinery status indication, heavy-duty equipment
Combined Indicator/SwitchIntegrated illumination with manual controlEmergency stop circuits, control desks
Multi-color IndicatorsProgrammable color outputs for status differentiationNetwork routers, medical diagnostic equipment
Remote IndicatorsSeparate light source and panel moduleAutomotive dashboards, aerospace control systems

3. Structure and Components

Typical construction includes:

  • Light Source: LED chips or filament bulbs with specific color/wavelength
  • Housing: Thermoplastic or metal body with mounting threads (e.g., M20, NPT)
  • Optical System: Diffused or focused lens for uniform light distribution
  • Electrical Interface: Screw terminals, PCB pins, or quick-connect terminals
  • Sealing Elements: Rubber gaskets for IP65+ protection ratings

4. Key Technical Specifications

ParameterSignificance
Operating Voltage RangeDetermines compatibility with control circuits (3-480V AC/DC)
Luminous Intensity (cd)Affects visibility in different lighting conditions
Color Wavelength (nm)Standardizes visual coding (e.g., 630nm red for warnings)
MTBF (Hours)Indicates reliability (LED: 50,000-100,000 hours)
IP RatingDefines environmental protection level
Response Time (ms)Critical for real-time status monitoring

5. Application Areas

  • Industrial: CNC machines, PLC control cabinets, factory automation
  • Transportation: Locomotive control panels, aircraft avionics
  • Medical: Patient monitors, imaging equipment status indicators
  • Consumer: Home appliance power indicators, audio equipment
  • Energy: Solar inverters, smart grid monitoring systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactILLINOX seriesModular design, IP69K rating
OmronXLDC12E-4AHUltra-compact LED indicator with 100,000-hour lifespan
Siemens8WA1000 seriesMulti-voltage capability (24-415V AC/DC)
EatonPilot Lights H45KShock-resistant filament lamps for heavy-duty use
TE ConnectivityCapLED Capacitive touch-enabled indicator

7. Selection Recommendations

Key considerations:

  • Environmental factors: Temperature range (-40 C to +85 C), vibration levels
  • Electrical compatibility: Voltage matching and circuit type (AC/DC)
  • Visibility requirements: Ambient light conditions and viewing distance
  • Certification needs: UL, CE, RoHS compliance for regulatory environments
  • Mechanical specifications: Panel cutout size (commonly 16/22/30mm)

Example: Selecting an IP67-rated LED indicator with 24V DC operation for a food processing plant's washdown area.

Industry Trends

Emerging developments include:

  • Integration with IoT systems for smart status monitoring
  • Miniaturization for high-density panel designs
  • RGB-LED technology for dynamic color coding
  • Energy harvesting indicators for self-powered operation
  • Enhanced durability coatings for extreme environments