Power Distribution, Surge Protectors

Image Part Number Description / PDF Quantity Rfq
PDU3MV6L2120B

PDU3MV6L2120B

Tripp Lite

PDU 3-PHASE METERED 208/120V

10

EPS-4126AG

EPS-4126AG

Chip Quik, Inc.

POWER STRIP 12 OUTLET BEIGE

0

PD1215-RM

PD1215-RM

Delta Electronics / Power

1U RACK MOUNT PDU 12 OUTLETS 2 F

564

TLP808NETG

TLP808NETG

Tripp Lite

POWER STRIP 8OUT 8'CORD

8260

1589T6D1

1589T6D1

Hammond Manufacturing

POWER STRIP14" 20A 6OUT 15'CR

0

PDUB20

PDUB20

Tripp Lite

PDU HOT SWAP 100-127V 16A

16

PDUMNH32HV

PDUMNH32HV

Tripp Lite

PDU MONITORED 230V 7.3KW 32A C13

0

1583T6A1

1583T6A1

Hammond Manufacturing

POWER STRIP 19"15A 6OUT 6'CRD GR

0

TLM609GF

TLM609GF

Tripp Lite

POWER STRIP 6OUT 9'CORD

16492

1583H12C1BKX

1583H12C1BKX

Hammond Manufacturing

POWER STRIP 19"15A 12OUT 6' CORD

0

OSP-H16-23-08-N1

OSP-H16-23-08-N1

Orion Fans

PDU 8OUT RACK 230V W/SENSORS

1

1585H11A1

1585H11A1

Hammond Manufacturing

POWER STRIP 48" 15A 11OUT 6'C

0

PDUMH30HV

PDUMH30HV

Tripp Lite

PDU METERED 208V 240V 30A 16 C13

8

15854H7B1

15854H7B1

Hammond Manufacturing

POWER STRIP 42" 15A 7OUT 15'C

0

2910346

2910346

Phoenix Contact

SURGE PROTECTION

73

1587H10B1

1587H10B1

Hammond Manufacturing

POWER STRIP 70" 15A 10OUT 15'

0

1587T12C1

1587T12C1

Hammond Manufacturing

POWER STRIP 70" 15A 12OUT 6'C

0

1587H19B1

1587H19B1

Hammond Manufacturing

POWER STRIP 70" 15A 19OUT 15'

0

TLP606USBB

TLP606USBB

Tripp Lite

SURGE PROTECTOR POWER STRIP 6 FT

83276

P12E22M

P12E22M

Panduit Corporation

MS PDU, 16AMP, (12)5-20R, NEMA L

2

Power Distribution, Surge Protectors

1. Overview

Power distribution and surge protection systems are critical components in modern electrical infrastructure. These systems ensure reliable power delivery, protect equipment from voltage spikes, and maintain operational continuity. Line protection devices safeguard against transient voltages, while power distribution units (PDUs) manage electricity allocation across networks. Surge protectors (SPDs) mitigate damage from lightning strikes or power surges. Together, these technologies form the backbone of stable power management in residential, commercial, and industrial applications.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Surge Protective Devices (SPDs)Divert transient surges to ground, maintain normal operationData centers, telecommunication systems
Isolation TransformersGalvanically isolate circuits, suppress electrical noiseHospitals, laboratory equipment
Uninterruptible Power Supplies (UPS)Provide backup power during outages, regulate voltageServer rooms, critical manufacturing systems
Power Distribution Units (PDUs)Monitor and distribute power to multiple outletsIT racks, data cabinets

3. Structure and Components

Typical surge protectors contain metal oxide varistors (MOVs), gas discharge tubes (GDTs), and thermal disconnects. PDUs feature hardened steel enclosures with multiple output sockets, integrated circuit breakers, and optional monitoring modules. UPS systems combine battery arrays, inverters, and automatic transfer switches. Advanced models incorporate IoT-enabled sensors for real-time voltage/current monitoring and predictive maintenance capabilities.

4. Key Technical Specifications

ParameterDescriptionImportance
Clamping VoltageMaximum voltage allowed during surgeDetermines protection level
Response TimeTime to activate protection (ns)Faster = better equipment safety
Energy Rating (Joules)Surge energy absorption capacityHigher = longer device lifespan
Network ManagementSNMP/Modbus connectivity supportEssential for system integration

5. Application Areas

  • IT Infrastructure: Server racks, network switches
  • Industrial: PLC systems, CNC machines
  • Healthcare: MRI/CT scanners, life-support systems
  • Renewables: Solar inverters, wind turbine controllers

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
APC by Schneider ElectricSmart-UPS On-LineDouble-conversion topology, 0ms transfer time
Eaton5P Series SPDHybrid technology, 400kA surge capacity
Phoenix ContactPT-IQ Power MonitorIoT-enabled energy analytics
RaritanPX Intelligent PDUPer-outlet metering, 15-year warranty

7. Selection Recommendations

Key considerations include:

  • Voltage compatibility with existing infrastructure
  • Surge current capacity (min. 20kA for critical systems)
  • Redundancy requirements for mission-critical loads
  • Environmental factors (temperature, humidity)
Case Study: Hospital CT scanner protection using Eaton's BDX-UPS system achieved 99.999% uptime through dual-battery redundancy and real-time diagnostics.

8. Industry Trends

Emerging developments include:

  • AI-powered predictive maintenance algorithms
  • Modular hybrid systems combining UPS + SPD functions
  • Integration with smart grid technologies
  • Increased adoption of wide bandgap semiconductors (SiC, GaN)
Market growth projections show 8.7% CAGR through 2030, driven by data center expansion and renewable energy integration requirements.