Power Line Filter Modules

Image Part Number Description / PDF Quantity Rfq
FLLE2032ASDI

FLLE2032ASDI

KEMET

EMI FILTER, 300VDC, 32A, THREAD

12

FLLE2010ASDB

FLLE2010ASDB

KEMET

EMI FILTER, 300VDC, 10A, FAST-ON

18

FLLE2006AQDB

FLLE2006AQDB

KEMET

EMI FILTER, 300VDC, 6A, FAST-ON,

24

FLLD3100AMHT6

FLLD3100AMHT6

KEMET

LINE FILTER 100A CHASS MNT

4

MA-2033

MA-2033

KEMET

POWER LINE FILTER, RFI FILTER, E

20

FLLD4064ATHT5

FLLD4064ATHT5

KEMET

LINE FILTER 64A CHASS MNT

10

FLLD32K5APVI1

FLLD32K5APVI1

KEMET

LINE FILTER 520VAC 2.5KA CHASS

0

FLLDU100A945I0

FLLDU100A945I0

KEMET

LINE FILTER 350VDC 250VAC CHAS

36

FLLD31K0APVI1

FLLD31K0APVI1

KEMET

LINE FILTER 520VAC 1KA CHASS MNT

2

FLLE2020APDI

FLLE2020APDI

KEMET

EMI FILTER, 300VDC, 20A, THREAD

18

FLLE2010AQDB

FLLE2010AQDB

KEMET

EMI FILTER, 300VDC, 10A, FAST-ON

15

FLLD3800APXI1

FLLD3800APXI1

KEMET

LINE FILTER 520VAC 800A CHASS

0

FLLE2016AUDB

FLLE2016AUDB

KEMET

EMI FILTER, 300VDC, 16A, FAST-ON

12

FLLD3016AMHT3

FLLD3016AMHT3

KEMET

LINE FILTER 16A CHASS MNT

0

FLLD3055AMHT5

FLLD3055AMHT5

KEMET

LINE FILTER 55A CHASS MNT

0

GTX-2300-Y00

GTX-2300-Y00

KEMET

EMI-RFI FILTERS 250VAC/560VDC,30

20

LF-220N

LF-220N

KEMET

POWER LINE FILTER, RFI FILTER, E

1

GTX-2100-Y00

GTX-2100-Y00

KEMET

EMI-RFI FILTERS 250VAC/560VDC,10

20

GT-22001V

GT-22001V

KEMET

POWER LINE FILTER, RIPPLE NOIS F

10

FLLDH016A025I0

FLLDH016A025I0

KEMET

LINE FILTER 440VDC 250VAC 16A CH

10

Power Line Filter Modules

1. Overview

Power Line Filter Modules (PLFMs) are electromagnetic interference (EMI) suppression devices designed to mitigate conducted noise in electrical systems. They ensure compliance with electromagnetic compatibility (EMC) standards by attenuating high-frequency noise while allowing desired power frequencies to pass. Their importance grows with increasing electrification and connectivity in modern applications like renewable energy systems, industrial automation, and medical electronics.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
Differential Mode FilterSuppresses asymmetric noise between live/neutral conductorsMotor drives, variable frequency drives
Common Mode FilterAttenuates symmetric noise between conductors and groundMedical imaging equipment, data centers
Combined FilterIntegrates differential and common mode suppressionIndustrial control cabinets, test equipment
High-Frequency FilterTargets noise above 1MHz with specialized componentsWireless base stations, satellite communication

3. Structure and Components

Typical PLFM construction includes: - Die-cast aluminum housing for EMI shielding - X/Y capacitors (ceramic or film type) for differential/common mode filtering - Toroidal or multi-hole inductors for noise suppression - Integrated thermal fuses and discharge resistors - IEC standard connectors (e.g., C13/C14) or terminal blocks - Epoxy sealing for environmental protection

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeTypically 150kHz-100MHzDetermines noise bandwidth attenuation
Voltage Rating100-600VAC/DCDefines operational safety margin
Insertion Loss10-100dB at target frequenciesQuantifies noise reduction capability
Current Capacity0.5-100AAffects power delivery capability
Temperature Range-40 C to +125 CEnsures environmental reliability

5. Application Areas

Key industries and equipment: - Industrial Automation: PLC control cabinets, CNC machines - Medical: MRI scanners, patient monitoring systems - Communication: 5G base stations, network servers - Renewable Energy: Solar inverters, wind turbine controllers - Aerospace: Avionics power systems, satellite payloads - Consumer Electronics: EV charging stations, smart home systems

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
SchaffnerFN 208080A rating, 3-phase filter for industrial drives
TDK-LambdaDFM1K1kW power line filter with medical safety certification
MTE CorporationPro-NetModular filter for industrial Ethernet applications
API TechnologiesPLF-300Military-grade filter for aerospace systems

7. Selection Guidelines

Key considerations: - Match voltage/current ratings with system requirements - Verify insertion loss curves at specific noise frequencies - Consider physical dimensions and cooling requirements - Ensure compliance with relevant standards (e.g., IEC 60939) - Evaluate environmental conditions (temperature, humidity, vibration) - Assess certification needs (CE, UL, MIL-STD)

8. Industry Trends

Market developments include: - Increasing demand for high-frequency filters (>10MHz) due to 5G/6G adoption - Miniaturization for EV and portable medical device applications - Integration with smart monitoring capabilities (IoT-enabled filters) - Growth in wide bandgap semiconductor compatible filters (SiC/GaN) - Stricter EMC regulations driving customized filter solutions - Market CAGR projected at 6.8% (2023-2030) according to industry reports

RFQ BOM Call Skype Email
Top