AC Fans

Image Part Number Description / PDF Quantity Rfq
UF360AAA12-H1C4A

UF360AAA12-H1C4A

Mechatronics

IMPELLER 360X167MM 115VAC

0

UF80B12-SWHR

UF80B12-SWHR

Mechatronics

FAN AXIAL 80X25MM 115VAC WIRE

0

UF12B12-BWHR-CC

UF12B12-BWHR-CC

Mechatronics

FAN AXIAL 120X38MM 115VAC WIRE

0

UF318AAA23-H1C4A-L32

UF318AAA23-H1C4A-L32

Mechatronics

FAN IMP MTRZ 318X154.4MM 230VAC

2

UF12A12-BTLR

UF12A12-BTLR

Mechatronics

FAN AXIAL 120X38MM 115VAC

107

LPT12A99-BTHR-2EM-EX

LPT12A99-BTHR-2EM-EX

Mechatronics

EC FAN AXIAL 120X120X38MM 100-24

0

UF12A12-BTSNR

UF12A12-BTSNR

Mechatronics

FAN 120X38MM 115V IP55 TERM

0

UF12AR12-BWLR

UF12AR12-BWLR

Mechatronics

FAN AXIAL 120X38MM 115VAC WIRE

0

UF15PC23-BTLR

UF15PC23-BTLR

Mechatronics

FAN AXIAL 172X150X51MM 230VAC

0

UF80AM23-BTHR-F

UF80AM23-BTHR-F

Mechatronics

AC FAN AXIAL 80X80X38MM 230V, HI

72

LPH92B99-BWHR-PC

LPH92B99-BWHR-PC

Mechatronics

EC FAN AXIAL 92 X 92 X 25MM W/PA

110

UF15KC12-BTHNR

UF15KC12-BTHNR

Mechatronics

FAN AXIAL 172X150X55MM 115VA IP5

72

UF15KC12-BWHNSR

UF15KC12-BWHNSR

Mechatronics

172X150X55MM 115V IP55 SALT FOG

414

UF190APA23-H1C2A

UF190APA23-H1C2A

Mechatronics

IMPELLER 190X70MM 230VAC

9

UF190APA12-H1C2A

UF190APA12-H1C2A

Mechatronics

IMPELLER 190X70MM 115VAC

36

LPC80B99-BTLR

LPC80B99-BTLR

Mechatronics

FAN AXIAL 80X25MM 90-264VAC EC

10

UF15KCR23-BWHR

UF15KCR23-BWHR

Mechatronics

FAN AXIAL 172X150X55MM 230VAC

0

UF9029CBP12H-L

UF9029CBP12H-L

Mechatronics

FAN BLWR CF 120VAC 420X150X130MM

3

UF12A12-STHR-M5

UF12A12-STHR-M5

Mechatronics

FAN AXIAL 120X38MM 115VAC TERM

15

UF12B12-BTHR

UF12B12-BTHR

Mechatronics

FAN AXIAL 120X25MM 115VAC

164

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction

RFQ BOM Call Skype Email