AC Fans

Image Part Number Description / PDF Quantity Rfq
AC4300H

AC4300H

ebm-papst Inc.

FAN AXIAL 119X32MM 85/265VAC

81

8550N

8550N

ebm-papst Inc.

FAN AXIAL 80X38MM 230VAC WIRE

122125

W2S130-AA03-46

W2S130-AA03-46

ebm-papst Inc.

FAN AXIAL

73

G2S097-DB03-01

G2S097-DB03-01

ebm-papst Inc.

FAN BLWR CENT 143X53MM 230VAC

0

4600N

4600N

ebm-papst Inc.

FAN AXIAL 119X38MM 115VAC TERM

94

55416.27070

55416.27070

ebm-papst Inc.

FAN BLOWER CF 180X108MM 115VAC

76

D2E133-DM47-A3

D2E133-DM47-A3

ebm-papst Inc.

BLOWER

748

4580N

4580N

ebm-papst Inc.

FAN AXIAL 119X38MM 230VAC TERM

5

S2E250-AM08-15

S2E250-AM08-15

ebm-papst Inc.

FAN AXIAL

3

W2E142-BB01-31

W2E142-BB01-31

ebm-papst Inc.

FAN AXIAL 230VAC 172X150X38MM

5

W3G250-HK19-11

W3G250-HK19-11

ebm-papst Inc.

FAN AXIAL 230V 280X80MM 1120CFM

0

8850A

8850A

ebm-papst Inc.

FAN AXIAL 80X38MM 230VAC TERM

0

W2D300-CP08-40

W2D300-CP08-40

ebm-papst Inc.

FAN AXIAL

5

W2S130-BM15-01

W2S130-BM15-01

ebm-papst Inc.

FAN AXIAL 150X55MM 115VAC WIRE

75

55410.81390

55410.81390

ebm-papst Inc.

FAN BLWR CF 180X96MM 120VAC TERM

0

W3G250-HH07-03

W3G250-HH07-03

ebm-papst Inc.

FAN AXIAL 230V 280X80MM 1000CFM

17

4536Z

4536Z

ebm-papst Inc.

AC FAN

88

9906

9906

ebm-papst Inc.

FAN AXIAL 119X25MM 115VAC TERM

95

8830TV

8830TV

ebm-papst Inc.

FAN AXIAL 76X37MM 115VAC WIRE

0

8560N

8560N

ebm-papst Inc.

AC AXIAL FAN

21

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction

RFQ BOM Call Skype Email
Top