AC Fans

Image Part Number Description / PDF Quantity Rfq
19020189A

19020189A

Comair Rotron

FAN AXIAL 254X89MM 115VAC CLE2T2

304

17000542A

17000542A

Comair Rotron

FAN AXL 135X38MM CR13538EC-2800

52

19028420A

19028420A

Comair Rotron

FAN AXIAL 120X38MM 110VAC MX2B1

266

19039202A

19039202A

Comair Rotron

FAN AXIAL 254X107MM 115V CLE2T5

286

19020169A

19020169A

Comair Rotron

FAN AXIAL 176X112MM 115VAC TNE2C

78

19028527A

19028527A

Comair Rotron

FAN AXIAL 119X39MM 115VAC MX2A4

278

19028423A

19028423A

Comair Rotron

FAN AXIAL 119X39MM 230VAC MX3B3

128

19031842A

19031842A

Comair Rotron

FAN AXIAL 172X55MM 115VAC MA2B3

264

17000659A

17000659A

Comair Rotron

FAN AXL 225X80MM CR2258-4000E1B

0

19028989A

19028989A

Comair Rotron

FAN AXIAL 119X39MM 230VAC MX77A2

395

17000657A

17000657A

Comair Rotron

FAN EC 225X80MM CR2258-3600E1B

0

19030519A

19030519A

Comair Rotron

FAN AXIAL 119X39MM 115VAC MX2B2

182

17000538A

17000538A

Comair Rotron

FAN AXL 120X38MM CR12038EC-3600

113

19028422A

19028422A

Comair Rotron

FAN AXIAL 120X38MM 115VAC MX2B3

437

17000658A

17000658A

Comair Rotron

FAN EC 225X80MM CR2258-3600E2B

0

17000660A

17000660A

Comair Rotron

FAN EC 225X80MM CR2258-4000E2B

0

19030389A

19030389A

Comair Rotron

FAN AXIAL 119X39MM 115VAC MX2B4

175

17000540A

17000540A

Comair Rotron

FAN AXIAL 80X25MM CR8025EC-4500

167

19031844A

19031844A

Comair Rotron

FAN AXIAL 172X55MM 230VAC MA77B3

66

19020174A

19020174A

Comair Rotron

FAN AXIAL 176X112MM 115VAC TNE2A

160

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction