Power Entry Connectors - Inlets, Outlets, Modules

Image Part Number Description / PDF Quantity Rfq
1301550158

1301550158

Woodhead - Molex

PWR ENT RCPT NON-NEMA PNL SCREW

1

1301440015

1301440015

Woodhead - Molex

PWR ENT PLUG NEMA5-20 R/A SCREW

3

1301490019

1301490019

Woodhead - Molex

FLANGED OUTLET NON-NEMA

5

1301450062

1301450062

Woodhead - Molex

PWR ENT PLUG NEMAL22-30 STR SCRW

1

1301410062

1301410062

Woodhead - Molex

PWR ENT PLUG NEMAL5-20 STR SCRW

26

1301490020

1301490020

Woodhead - Molex

FLANGED OUTLET NEMA L7-15

5

1301490061

1301490061

Woodhead - Molex

PWR ENT RCPT NEMAL16-30 PNL SCRW

2

1301490031

1301490031

Woodhead - Molex

FLANGED INLET NEMA L16-20

2

1301470158

1301470158

Woodhead - Molex

PWR ENT RCPT NEMAL6-30 WALL SCRW

3

1301450066

1301450066

Woodhead - Molex

PWR ENT RCPT NON-NEMA STR SCREW

6

1301490043

1301490043

Woodhead - Molex

FLANGED OUTLET NEMA L15-20

2

1301490006

1301490006

Woodhead - Molex

FLANGED INLET W/1407 INS

5

1301490056

1301490056

Woodhead - Molex

FLANGED OUTLET NON-NEMA

2

1301420051

1301420051

Woodhead - Molex

PWR ENT PLUG NEMA6-50 STR SCREW

2

1301420052

1301420052

Woodhead - Molex

PWR ENT RCPT NEMA6-50 STR SCREW

10

1301440044

1301440044

Woodhead - Molex

PWR ENT RCPT NEMA5-15 STR SCREW

10

1301450019

1301450019

Woodhead - Molex

HI-AMP TURNEX L16-20 PLUG 3P4W

3

1301440036

1301440036

Woodhead - Molex

PWR ENT PLUG NEMA5-15 STR SCREW

63

1301440048

1301440048

Woodhead - Molex

5-15 LIGHTED CONN HI-IMPACT

9

1301470141

1301470141

Woodhead - Molex

PWR ENT RCPT NEMAL5-20 WALL SCRW

2

Power Entry Connectors - Inlets, Outlets, Modules

1. Overview

Power entry connectors are electro-mechanical devices designed to safely establish electrical connections between equipment and power sources. They serve as critical interfaces in AC/DC power systems, ensuring reliable energy transmission while meeting safety and regulatory standards. Their importance spans across industries where stable power delivery and user protection are paramount.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
IEC Appliance InletsStandardized C13/C19 types, detachable connectionsComputers, servers, medical devices
NEMA ReceptaclesNon-locking/Locking configurations (5-15P/R, L5-30P/R)Industrial machinery, construction equipment
Modular Power Entry ModulesIntegrated filtering, switching, and fused protectionData centers, test equipment
Medical-Grade ConnectorsDouble-insulated, low-leakage current designPatient monitors, MRI machines

3. Structure and Components

Typical construction includes:

  • Thermoplastic housing (UL94 V-0 rated)
  • Copper alloy contact springs (phosphor bronze)
  • Insulation barriers (glass-reinforced epoxy)
  • Termination options: Screw/clamp terminals or PCB mounts
  • Integrated features: EMI filters, circuit breakers, LED indicators

4. Key Technical Specifications

ParameterSignificance
Rated Voltage (50-600V AC/DC)Determines maximum operating potential
Current Rating (1-63A)Defines safe continuous load capacity
Contact Resistance (<5m )Impacts power efficiency and thermal performance
Dielectric Withstanding Voltage (1.5-4kV)Safety isolation capability
Temperature Range (-40 C to +125 C)Environmental operational limits
IP Rating (IP20-IP67)Protection against solids/liquids ingress

5. Application Fields

  • Consumer Electronics: Desktop PCs, printers, home appliances
  • Industrial Automation: PLC cabinets, motor drives, robotics
  • Medical Equipment: Ultrasound machines, ventilators, lab analyzers
  • Data Centers: Server racks, PDU units, UPS systems
  • Renewable Energy: Solar inverters, wind turbine controllers

6. Leading Manufacturers and Products

ManufacturerRepresentative Product
TE ConnectivityPower-Entry Modules with integrated filters
Amphenol CorporationSeries 1300 IEC C13 inlets
Molex IncorporatedMini-Fit Jr. power entry systems
Phoenix ContactTRABTECH power entry solutions

7. Selection Guidelines

Key consideration factors:

  1. Electrical Requirements: Match voltage/current ratings with system needs
  2. Environmental Conditions: Consider temperature, humidity, and vibration
  3. Certification Standards: UL/CSA, IEC 60320, medical 60601-1 compliance
  4. Mechanical Durability: Minimum 10,000 mating cycles for industrial use
  5. Space Constraints: Panel cutout dimensions and PCB footprint
  6. Protection Features: Surge suppression, overcurrent protection integration

8. Industry Trends

Emerging developments include:

  • Miniaturization: 30% size reduction in IEC connectors for portable devices
  • High-Power Density: 600V/100A modules for EV charging infrastructure
  • Smart Connectivity: Integrated power-line communication (PLC) capabilities
  • Eco-friendly Materials: Halogen-free thermoplastics adoption (growing at 15% CAGR)
  • Modular Designs: Hot-swappable power entry systems for 24/7 operations
RFQ BOM Call Skype Email
Top