Heavy Duty Connectors - Frames

Image Part Number Description / PDF Quantity Rfq
09300241704

09300241704

HARTING

HAN 24B METAL DOCKING FRAME (35M

10

C146P06001G8

C146P06001G8

Tuchel / Amphenol

FRAME FIXED MALE SZE6 FOR 2MOD

0

1182087

1182087

Phoenix Contact

FRAME MODULAR SNAP-IN

674407

09300109301

09300109301

HARTING

10B BULKHEAD REAR FIT HOUSING FR

45

09110349973

09110349973

HARTING

34 HPR EASYCON FRAME FOR 4XHC650

0

09110009942

09110009942

HARTING

FRAME 4XHC250-F (INVERS)

0

1110900000

1110900000

Weidmuller

COUNTER FRAME SZ4

0

1852972

1852972

Phoenix Contact

FRAME PANEL MOUNT SZ1 FOR 2MOD

21

1417405

1417405

Phoenix Contact

FRAME HINGED FOR 4MOD

24302

09140241711

09140241711

HARTING

FRAME PANEL MOUNT FMALE FOR 6MOD

30

1103250-1

1103250-1

TE Connectivity AMP Connectors

FRAME FIXED SZ8 FOR 6MOD

0

T0924049044-200

T0924049044-200

TE Connectivity AMP Connectors

T0924049044-200

0

1417400

1417400

Phoenix Contact

FRAME HINGED FOR 4MOD

80

09140061711

09140061711

HARTING

FRAME PANEL MOUNTING FOR 2MOD

0

T2070244001-000

T2070244001-000

TE Connectivity AMP Connectors

H24BN-T6

0

T0924015115-000

T0924015115-000

TE Connectivity AMP Connectors

T0924015115-000

120

09140241716

09140241716

HARTING

HAN 24B MODULAR DOCKING FRAME FO

0

09110009973

09110009973

HARTING

FRAME FIXED MALE SZ24HPR FOR3MOD

0

1758500000

1758500000

Weidmuller

FRAME FIXED MALE SZ8 FOR 7MOD

15235

C146S16002G8

C146S16002G8

Tuchel / Amphenol

FRAME FIXED FMALE SZE16 FOR 5MOD

0

Heavy Duty Connectors - Frames

1. Overview

Heavy Duty Connectors - Frames are robust mechanical structures designed to support and protect high-current or high-voltage electrical connections in demanding environments. These frames serve as critical components in industrial systems, ensuring reliable power transmission and signal integrity while withstanding mechanical stress, temperature extremes, and environmental contaminants. Their importance spans across automation, energy infrastructure, and transportation sectors where failure prevention is paramount.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Modular Frame SystemsCustomizable slot configurations, tool-less assemblyAutomated production lines
Panel Mount FramesFront-access design, integrated strain reliefControl cabinets in chemical plants
Weatherproof FramesIP67+ sealing, corrosion-resistant coatingsOutdoor power distribution units
High-Voltage FramesExtended creepage distances, arc-resistant materialsRailway traction systems

3. Structure and Components

Typical frames consist of: - Aluminum Alloy Housing: Provides structural integrity with weight efficiency - Copper Alloy Conductors: Ensures low-resistance electrical paths ( 98% conductivity) - Polyamide Insulation: Maintains dielectric strength up to 8kV - Mechanical Locking System: Anti-vibration latches meeting MIL-STD-810G - Thermal Management Fins: Dissipates heat at current loads >200A

4. Key Technical Specifications

ParameterValue RangeImportance
Current Rating100-5000ADetermines power transmission capacity
Voltage RangeAC 50V-1500V / DC 50V-2000VSafety and insulation requirements
IP RatingIP20-IP69KEnvironmental protection level
Contact Resistance 0.5m Influences energy efficiency
Operating Temperature-40 C to +150 CMaterial stability indicator

5. Application Fields

  • Industrial Automation: Robotic welding systems, CNC machine tooling
  • Renewable Energy: Wind turbine converters, solar inverter arrays
  • Transportation: Electric vehicle charging stations, locomotive power systems
  • Heavy Machinery: Mining equipment control panels, construction vehicle hydraulics

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesTechnical Highlights
TE ConnectivityDEUTSCH HD Frame Series1500V isolation, -55 C cold resistance
Amphenol IndustrialPowerlok HD Frames3000A capacity, quick-mate design
Phoenix ContactHeavycon SystemModular hybrid power/signal integration

7. Selection Recommendations

Key considerations include: - Electrical Requirements: Match current/voltage ratings with system specifications - Environmental Factors: Consider humidity, vibration, and chemical exposure - Compliance Standards: UL 1977, IEC 60998, or industry-specific certifications - Future Expansion: Select modular designs for scalability - Cost Analysis: Balance upfront investment vs. lifecycle maintenance costs

Example: For offshore wind turbine applications, specify IP68 frames with electroless nickel plating and 1500V insulation to withstand saltwater corrosion and high-voltage demands.

8. Industry Trends

Emerging developments include: - Miniaturization with enhanced current density (40% size reduction by 2027) - Smart frames integrating IoT sensors for predictive maintenance - Adoption of graphene-enhanced composites for thermal management - Increased demand for 1500V+ DC compatible designs in renewable energy - Standardization initiatives for cross-manufacturer interoperability (IEC 61984 amendments)

RFQ BOM Call Skype Email