Fuses

Image Part Number Description / PDF Quantity Rfq
MRT 3.15-BULK

MRT 3.15-BULK

Bel Fuse, Inc.

FUSE BRD MNT 3.15A 250VAC RADIAL

9394

3JQ 1-R

3JQ 1-R

Bel Fuse, Inc.

FUSE GLASS 1A 350VAC 140VDC 2AG

0

0680L3000-21

0680L3000-21

Bel Fuse, Inc.

FUSE BRICK SMD 2410 SLOW 3A

0

GSA 1-R

GSA 1-R

Bel Fuse, Inc.

FUSE CERAMIC 1A 250VAC 3AB 3AG

727

0697H4000-01

0697H4000-01

Bel Fuse, Inc.

FUSE BRD MNT 4A 350VAC 72VDC

1246

0ADAC4000-BE

0ADAC4000-BE

Bel Fuse, Inc.

FUSE CERM 4A 600VAC/VDC

570

2JS 4-R

2JS 4-R

Bel Fuse, Inc.

FUSE GLASS 4A 350VAC 140VDC 2AG

1793

RSTA 6.3 AMMO

RSTA 6.3 AMMO

Bel Fuse, Inc.

FUSE BRD MNT 6.3A 250VAC/63VDC

3

0ADKP2000-RE

0ADKP2000-RE

Bel Fuse, Inc.

FUSE CERAMIC 2A 600VAC/500VDC

21

0697H6300-01

0697H6300-01

Bel Fuse, Inc.

FUSE BRD MNT 6.3A 350VAC 72VDC

0

C2Q 750

C2Q 750

Bel Fuse, Inc.

FUSE BOARD MNT 750MA 32VAC 63VDC

4885

RSTA 2.5 AMMO

RSTA 2.5 AMMO

Bel Fuse, Inc.

FUSE BRD MNT 2.5A 250VAC/63VDC

0

5ST 2-R

5ST 2-R

Bel Fuse, Inc.

FUSE GLASS 2A 250VAC 5X20MM

35147

RST 2-BULK

RST 2-BULK

Bel Fuse, Inc.

FUSE BOARD MOUNT 2A 250VAC RAD

25207

0679H0750-05

0679H0750-05

Bel Fuse, Inc.

FUSE BRD MNT 750MA 350VAC 72VDC

742

5TT 1-R

5TT 1-R

Bel Fuse, Inc.

FUSE GLASS 1A 250VAC 5X20MM

0

0ADAP0200-RE

0ADAP0200-RE

Bel Fuse, Inc.

FUSE CERM 0.2A 600V AXL

961

0ADBP3000-RE

0ADBP3000-RE

Bel Fuse, Inc.

FUSE CERM 3A 1000V AXL

944

0ADAC1600-BE

0ADAC1600-BE

Bel Fuse, Inc.

FUSE CERM 1.6A 600VAC/VDC

326

RST 200-BULK

RST 200-BULK

Bel Fuse, Inc.

FUSE BOARD MNT 200MA 250VAC RAD

308

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top