Fuses

Image Part Number Description / PDF Quantity Rfq
0680L9100-01

0680L9100-01

Bel Fuse, Inc.

FUSE BRICK SMD 2410 SLOW 10A

0

0686F1500-01

0686F1500-01

Bel Fuse, Inc.

FUSE BRD MNT 1.5A 63VDC 0603

3215

3AG 7-R

3AG 7-R

Bel Fuse, Inc.

FUSE GLASS 7A 250VAC 3AB 3AG

1589

SSQ 4

SSQ 4

Bel Fuse, Inc.

FUSE BRD MNT 4A 125VAC/VDC 2SMD

445

SST 4/5K

SST 4/5K

Bel Fuse, Inc.

FUSE BRD MNT 4A 125VAC/VDC 2SMD

0

0678H1250-02

0678H1250-02

Bel Fuse, Inc.

FUSE SMT 3912 ENH BRK 250V 1.25A

1488

0678D0630-02

0678D0630-02

Bel Fuse, Inc.

FUSE SMT 3912 FAST 250V 630MA

0

0680L5000-25

0680L5000-25

Bel Fuse, Inc.

FUSE BRICK SMD 2410 SLOW 5A

0

0680L1500-05

0680L1500-05

Bel Fuse, Inc.

FUSE BRICK SMD 2410 SLOW 1.5A

3610

RST 2-BULK-SHORT

RST 2-BULK-SHORT

Bel Fuse, Inc.

FUSE BRD MNT 2A 250VAC RADIAL

0

MRT 500AMMO

MRT 500AMMO

Bel Fuse, Inc.

FUSE BRD MNT 500MA 250VAC RADIAL

0

5ST 1.25-R

5ST 1.25-R

Bel Fuse, Inc.

FUSE GLASS 1.25A 250VAC 5X20MM

1457

0ADAP2500-RE

0ADAP2500-RE

Bel Fuse, Inc.

FUSE CERM 2.5A 600V AXL

90

RST 200-BULK-SHORT

RST 200-BULK-SHORT

Bel Fuse, Inc.

FUSE BRD MNT 200MA 250VAC RADIAL

0

0679H7000-01

0679H7000-01

Bel Fuse, Inc.

FUSE BOARD MNT 7A 350VAC 60VDC

159

SST 2

SST 2

Bel Fuse, Inc.

FUSE BOARD MNT 2A 125VAC/VDC SMD

0

0698Q2500-02

0698Q2500-02

Bel Fuse, Inc.

FUSE 2.5A 350V RADIAL

0

0685P9250-01

0685P9250-01

Bel Fuse, Inc.

FUSE 25A 50VDC FAST 1206 SMD

2534

MRT 80AMMO

MRT 80AMMO

Bel Fuse, Inc.

FUSE BOARD MOUNT 80MA 250VAC RAD

0

0679L0375-01

0679L0375-01

Bel Fuse, Inc.

FUSE BRD MNT 375MA 125VAC/VDC

650

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top