Fuses

Image Part Number Description / PDF Quantity Rfq
0034.4217

0034.4217

Schurter

FUSE BOARD MNT 630MA 125VAC/VDC

100

7022.0620

7022.0620

Schurter

FUSE CERAMIC 1.6A 500VAC 3AB 3AG

0

0034.4219

0034.4219

Schurter

FUSE BOARD MNT 750MA 125VAC/VDC

63

0034.6923

0034.6923

Schurter

FUSE BOARD MOUNT 6.3A 250VAC RAD

590

3412.0120.22

3412.0120.22

Schurter

FUSE BRD MNT 36VAC 63VDC 0603

1380

3413.0009.26

3413.0009.26

Schurter

FUSE BRD MNT 200MA 125VAC 63VDC

0

0034.4245

0034.4245

Schurter

FUSE BOARD MNT 400MA 125VAC/VDC

63

3403.0012.11

3403.0012.11

Schurter

FUSE BOARD MNT 400MA 250VAC/VDC

1

7100.1019.13

7100.1019.13

Schurter

FUSE BOARD MOUNT 2.5A 250VAC RAD

100

3413.0329.26

3413.0329.26

Schurter

FUSE BOARD MOUNT 12A 32VAC 63VDC

0

3402.0004.24

3402.0004.24

Schurter

FUSE BOARD MOUNT 100MA 63VAC/VDC

0

0034.5628.22

0034.5628.22

Schurter

FUSE GLASS 12.5A 250VAC 5X20MM

0

0034.5611.11

0034.5611.11

Schurter

FUSE GLASS 250MA 250VAC 5X20MM

78

0034.6719

0034.6719

Schurter

FUSE BRD MNT 2.5A 250VAC 125VDC

3939

3410.0035.03

3410.0035.03

Schurter

FUSE BOARD MNT 2A 125VAC/VDC SMD

0

0001.2511.PT

0001.2511.PT

Schurter

FUSE CERM 5A 250VAC 150VDC 5X20

901

7100.1164.96

7100.1164.96

Schurter

FUSE BOARD MNT 800MA 250VAC/VDC

0

8020.5011.G

8020.5011.G

Schurter

SHT 6.3X32 FUSE 1A T

458

3414.0112.22

3414.0112.22

Schurter

FUSE BOARD MNT 375MA 32VDC 0402

1980

3413.0117.26

3413.0117.26

Schurter

FUSE BOARD MNT 1.5A 32VAC 63VDC

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top