Fuses

Image Part Number Description / PDF Quantity Rfq
BK/AGC-2-1/4-R

BK/AGC-2-1/4-R

PowerStor (Eaton)

FUSE GLASS 2.25A 250VAC 3AB 3AG

62

C1F 500

C1F 500

Bel Fuse, Inc.

FUSE 500MA 125VAC FAST 1206

722

APM-I-40A

APM-I-40A

OptiFuse

FUSE AUTO 40A 32VDC BLADE MINI

0

74-5FC10A

74-5FC10A

NTE Electronics, Inc.

FUSE CERAMIC 10A 250VAC 5X20MM

458

BK/AGX-1/10

BK/AGX-1/10

PowerStor (Eaton)

FUSE GLASS 100MA 250VAC 8AG

25

0312.600HXP

0312.600HXP

Wickmann / Littelfuse

FUSE GLASS 600MA 250VAC 3AB 3AG

192

0251010.VXL

0251010.VXL

Wickmann / Littelfuse

FUSE BOARD MOUNT 10A 125VAC/VDC

0

023902.5MXEP

023902.5MXEP

Wickmann / Littelfuse

FUSE GLASS 2.5A 250VAC 5X20MM

0

74-6FG750MA

74-6FG750MA

NTE Electronics, Inc.

FUSE GLASS 750MA 250VAC 6X30MM

932

7010.6340.13

7010.6340.13

Schurter

FUSE BOARD MNT 500MA 125VAC/VDC

195

1206SFP500F/32-2

1206SFP500F/32-2

Wickmann / Littelfuse

FUSE BOARD MOUNT 5A 32VDC 1206

2640

SF-1206SP300M-2

SF-1206SP300M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 3A 32VDC 1206

4747

0278.400V

0278.400V

Wickmann / Littelfuse

FUSE BOARD MNT 400MA 125VAC/VDC

10

0224001.MXP

0224001.MXP

Wickmann / Littelfuse

FUSE GLASS 1A 250VAC 125VDC 2AG

1446

BK/C518S-2-R

BK/C518S-2-R

PowerStor (Eaton)

FUSE GLASS 2A 250VAC 2AG

0

023406.3MXEP

023406.3MXEP

Wickmann / Littelfuse

FUSE CERAMIC 6.3A 250VAC 5X20MM

0

TSC-3.5A

TSC-3.5A

OptiFuse

GLASS - 5X20MM (UL), SLOW 3.5A

1245

TR1/6125TD1.5-R

TR1/6125TD1.5-R

PowerStor (Eaton)

FUSE BOARD MNT 1.5A 125VAC 60VDC

1388

20101250001

20101250001

Wickmann / Littelfuse

FUSE GLASS 125MA 250VAC 5X20MM

0

0435004.KR

0435004.KR

Wickmann / Littelfuse

FUSE BOARD MOUNT 4A 32VDC 0402

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top