Fuseholders

Image Part Number Description / PDF Quantity Rfq
03453HS7HXLN

03453HS7HXLN

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

0

L60030C1PQDINR

L60030C1PQDINR

Wickmann / Littelfuse

FUSE BLOK CART 600V 30A DIN RAIL

1985

80000000005

80000000005

Wickmann / Littelfuse

FUSE HLDR CART 250V 6.3A PNL MNT

0

57600000001

57600000001

Wickmann / Littelfuse

FUSE HOLDER TR5 6.3A 250V

0

LFG600201CDINR

LFG600201CDINR

Wickmann / Littelfuse

FUSE BLOK CART 600V 20A DIN RAIL

8

03440402X

03440402X

Wickmann / Littelfuse

FUSE HOLDER CART 16V 20A PNL MNT

0

03540907ZXGY

03540907ZXGY

Wickmann / Littelfuse

FUSE BLOCK CART 600V 30A CHASSIS

0

57100000001

57100000001

Wickmann / Littelfuse

FUSE HOLDER RADIAL 250V 6.3A PCB

20560

03453HS1H

03453HS1H

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

348

0LEX00JJX

0LEX00JJX

Wickmann / Littelfuse

FUSE HLDR CART 600V 30A IN LINE

0

04820001ZXP

04820001ZXP

Wickmann / Littelfuse

FUSE HLDR BLADE 125V 15A PNL MNT

0

02540006Z

02540006Z

Wickmann / Littelfuse

FUSE BLOCK CART 300V 10A CHASSIS

0

LFC600601CID

LFC600601CID

Wickmann / Littelfuse

FUSE BLOK CART 600V 60A DIN RAIL

501

04820007ZXB

04820007ZXB

Wickmann / Littelfuse

FUSE HOLDER BLADE 125V 15A PCB

0

03453HS3ZX010

03453HS3ZX010

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

0

0LEY0ABSX

0LEY0ABSX

Wickmann / Littelfuse

FUSE HLDR CART 600V 30A IN LINE

0

01090002Z

01090002Z

Wickmann / Littelfuse

FUSE CLIP CART 600V 60A CHASSIS

0

PDM33001ZXM

PDM33001ZXM

Wickmann / Littelfuse

HWB12 - WITH CLEAR COVER

0

03440250X

03440250X

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

0

03420838X

03420838X

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

0

Fuseholders

1. Overview

Fuseholders are mechanical devices designed to safely house and connect fuses into electrical circuits. They ensure reliable mounting, electrical continuity, and safe isolation of fuses during overcurrent protection. As critical components in circuit protection systems, fuseholders prevent equipment damage and fire hazards by enabling controlled interruption of excessive current flow. Their importance spans industries such as power distribution, automotive, and industrial automation, where electrical safety and system reliability are paramount.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Panel Mount FuseholdersEnclosed design with front-accessible fuse compartmentIndustrial control panels, HVAC systems
Base Mount FuseholdersModular design with removable fuse basePower distribution units, electrical substations
Cartridge FuseholdersCylindrical design for DIN-rail mountingProcess automation systems, machinery
SMT (Surface Mount) FuseholdersMiniaturized PCB-mount designConsumer electronics, telecommunications

3. Structure and Components

Typical fuseholders consist of: - Insulating housing (thermoplastic/phenolic resin) - Contact springs (phosphor bronze or beryllium copper) - Fuse retention mechanism (screw/clamp terminals) - Terminal connections (solder tags, PCB pins, or cable lugs) - Arc suppression chamber (ceramic/insulating barriers) The design ensures mechanical stability, low contact resistance (<10m ), and dielectric strength up to 2500VAC.

4. Key Technical Specifications

ParameterTypical RangeImportance
Voltage Rating6-1000V AC/DCDetermines circuit compatibility
Current Rating0.5-630ADefines maximum operational current
Breaking Capacity10kA-50kASafety during fault conditions
Response Time1ms-10sProtection speed for sensitive components
Temperature Range-40 C to +125 CEnvironmental reliability
IP RatingIP20-IP67Protection against dust/water ingress

5. Application Fields

  • Energy: Solar inverters, battery management systems
  • Automotive: EV charging stations, ECU protection
  • Industrial: PLC control circuits, motor drives
  • Telecom: 5G base stations, network switches
  • Aerospace: Avionics power distribution

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesNotable Features
LittelfusePOLO Panel MountModular design with visual indicators
MersenActi 9 seriesHigh breaking capacity (100kA)
EatonCircuit Protection EnclosuresUL94 V-0 rated materials
Bel Fuse0ZC SeriesSurface-mount with over-temperature cutoff

7. Selection Recommendations

Key considerations include: - Matching voltage/current ratings with system requirements - Environmental factors (temperature, vibration, humidity) - Accessibility requirements for fuse replacement - Compliance with standards (UL/IEC/EN) - Short-circuit current capacity of the installation - Mounting orientation and space constraints

Industry Trends and Future Outlook

Emerging trends include: - Miniaturization for EV and portable electronics - Integration with smart monitoring systems (IoT-enabled fuseholders) - Development of RoHS-compliant materials - High-voltage DC compatibility for renewable energy systems - Improved arc flash mitigation technologies The global market is projected to grow at 5.8% CAGR through 2027, driven by electric vehicle adoption and industrial automation demands.

RFQ BOM Call Skype Email
Top