Fuseholders

Image Part Number Description / PDF Quantity Rfq
LPM-11C-14R

LPM-11C-14R

OptiFuse

MINI FUSEHOLDER-CLEAR,20A-14AWG

0

3555-2

3555-2

Keystone Electronics Corp.

FUSE BLOCK BLADE 500V 50A PCB

979736680

0751.0099

0751.0099

Schurter

FUSE CLIP CARTRIDGE 600V 16A PCB

315815000

LFG480602CDINR

LFG480602CDINR

Wickmann / Littelfuse

FUSE BLOK CART 480V 60A DIN RAIL

92

3512P

3512P

Keystone Electronics Corp.

FUSE CLIP CARTRIDGE 15A PCB

7900

LPR-06B-12R

LPR-06B-12R

OptiFuse

REG. FUSEHOLDER, 30A-12AWG

1159

03450121H

03450121H

Wickmann / Littelfuse

FUSE HLDR CARTRIDGE 600V 16A PCB

26

BLR-310-G

BLR-310-G

OptiFuse

REG. FUSE BLOCK, 10 POLE GROUND

0

LFC600602CID

LFC600602CID

Wickmann / Littelfuse

FUSE BLOK CART 600V 60A DIN RAIL

395

LFJ606001C

LFJ606001C

Wickmann / Littelfuse

FUSE BLOCK CART 600V 600A DIN

3

BLR-1110

BLR-1110

OptiFuse

REGULAR FUSE BLOCK, 10 POLE

0

3522-3

3522-3

Keystone Electronics Corp.

FUSE CLIP BLADE 500V 30A PCB

0

BK/S-8002-12-R

BK/S-8002-12-R

PowerStor (Eaton)

FUSE BLOCK CART 300V CHASS MNT

97

002540211

002540211

Altech Corporation

FUSE HOLDEREFH10 DC PV1P+LED 100

0

74-IFHMAL15

74-IFHMAL15

NTE Electronics, Inc.

IN LINE FUSE HOLDER

300

03420048X

03420048X

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

0

03450711H

03450711H

Wickmann / Littelfuse

FUSE HLDR CART 600V 20A PNL MNT

0

03453LF8ZX010

03453LF8ZX010

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

67

03452LF2X

03452LF2X

Wickmann / Littelfuse

FUSE HLDR CART 250V 10A PNL MNT

0

03452LS1H

03452LS1H

Wickmann / Littelfuse

FUSE HLDR CART 250V 10A PNL MNT

0

Fuseholders

1. Overview

Fuseholders are mechanical devices designed to safely house and connect fuses into electrical circuits. They ensure reliable mounting, electrical continuity, and safe isolation of fuses during overcurrent protection. As critical components in circuit protection systems, fuseholders prevent equipment damage and fire hazards by enabling controlled interruption of excessive current flow. Their importance spans industries such as power distribution, automotive, and industrial automation, where electrical safety and system reliability are paramount.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Panel Mount FuseholdersEnclosed design with front-accessible fuse compartmentIndustrial control panels, HVAC systems
Base Mount FuseholdersModular design with removable fuse basePower distribution units, electrical substations
Cartridge FuseholdersCylindrical design for DIN-rail mountingProcess automation systems, machinery
SMT (Surface Mount) FuseholdersMiniaturized PCB-mount designConsumer electronics, telecommunications

3. Structure and Components

Typical fuseholders consist of: - Insulating housing (thermoplastic/phenolic resin) - Contact springs (phosphor bronze or beryllium copper) - Fuse retention mechanism (screw/clamp terminals) - Terminal connections (solder tags, PCB pins, or cable lugs) - Arc suppression chamber (ceramic/insulating barriers) The design ensures mechanical stability, low contact resistance (<10m ), and dielectric strength up to 2500VAC.

4. Key Technical Specifications

ParameterTypical RangeImportance
Voltage Rating6-1000V AC/DCDetermines circuit compatibility
Current Rating0.5-630ADefines maximum operational current
Breaking Capacity10kA-50kASafety during fault conditions
Response Time1ms-10sProtection speed for sensitive components
Temperature Range-40 C to +125 CEnvironmental reliability
IP RatingIP20-IP67Protection against dust/water ingress

5. Application Fields

  • Energy: Solar inverters, battery management systems
  • Automotive: EV charging stations, ECU protection
  • Industrial: PLC control circuits, motor drives
  • Telecom: 5G base stations, network switches
  • Aerospace: Avionics power distribution

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesNotable Features
LittelfusePOLO Panel MountModular design with visual indicators
MersenActi 9 seriesHigh breaking capacity (100kA)
EatonCircuit Protection EnclosuresUL94 V-0 rated materials
Bel Fuse0ZC SeriesSurface-mount with over-temperature cutoff

7. Selection Recommendations

Key considerations include: - Matching voltage/current ratings with system requirements - Environmental factors (temperature, vibration, humidity) - Accessibility requirements for fuse replacement - Compliance with standards (UL/IEC/EN) - Short-circuit current capacity of the installation - Mounting orientation and space constraints

Industry Trends and Future Outlook

Emerging trends include: - Miniaturization for EV and portable electronics - Integration with smart monitoring systems (IoT-enabled fuseholders) - Development of RoHS-compliant materials - High-voltage DC compatibility for renewable energy systems - Improved arc flash mitigation technologies The global market is projected to grow at 5.8% CAGR through 2027, driven by electric vehicle adoption and industrial automation demands.