Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
004110333

004110333

Altech Corporation

FUSENH1DCM50A750VDC

0

004255514

004255514

Altech Corporation

FUSEHVVVC537MM80A 10/24KVD=68STR

0

002625025

002625025

Altech Corporation

FUSE CARTRIDGE 25A 700VDC

0

004110229

004110229

Altech Corporation

FUSENH1CDCM160A440VDC

0

2C8X32AM/I

2C8X32AM/I

Altech Corporation

FUSE CARTRIDGE 2A 400VAC

0

63C22X58SC

63C22X58SC

Altech Corporation

FUSE CYLINDER 10 22X58MM63A660VS

0

004113740

004113740

Altech Corporation

FUSENH2GGM63A1200VAC STD. INDICA

0

004113708

004113708

Altech Corporation

FUSENH1GGM35A1000VAC

0

004237511

004237511

Altech Corporation

FUSEHVVVTE442MM40A 6/12KVD=53STR

0

004265006

004265006

Altech Corporation

FUSEHVVVC537MM10A 20/36KVD=53STR

0

002312406

002312406

Altech Corporation

FUSE CARTRIDGE 20A 500VAC/400VDC

10

004111174

004111174

Altech Corporation

FUSENH00CGGM6A690VAC WITH STRIKE

0

004373623

004373623

Altech Corporation

FUSENH1ARG400A690VAC 200KA ACFOR

0

002625306

002625306

Altech Corporation

FUSE CARTRIDGE 16A 700VDC

0

004303623

004303623

Altech Corporation

FUSENH1ARG400A1000VAC 200KA ACFO

0

8C22X58GI/I

8C22X58GI/I

Altech Corporation

FUSE CYLINDER WIND 10 2X58MM 8A

0

002635109

002635109

Altech Corporation

FUSE 16A 690VAC/700VDC

0

004246513

004246513

Altech Corporation

FUSEHVVVTD442MM63A 10/17.5KVD=68

0

004745226

004745226

Altech Corporation

FUSENH3ARM500A690VAC 200KA AC

0

2C10X38AM

2C10X38AM

Altech Corporation

FUSE CARTRIDGE 2A 500VAC 5AG

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems

RFQ BOM Call Skype Email
Top