Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
FWA-50A21F

FWA-50A21F

Eaton

FUSE CARTRIDGE 50A 150VAC/VDC

0

170M6598

170M6598

Eaton

FUSE SQUARE 1KA 1.3KVAC RECT

0

FRS-R-350

FRS-R-350

Eaton

FUSE CRTRDGE 350A 600VAC/250VDC

1

170M5194

170M5194

Eaton

FUSE SQUARE 500A 1.3KVAC RECT

0

200M09C

200M09C

Eaton

FUSE CRTRDGE 200A 600VAC/250VDC

0

170M6416

170M6416

Eaton

FUSE SQUARE 1.25KA 700VAC RECT

0

170M3565

170M3565

Eaton

FUSE SQUARE 200A 700VAC RECT

0

FNQ-R-2-1/2

FNQ-R-2-1/2

Eaton

FUSE CARTRIDGE 2.5A 600VAC 5AG

10

170M5690

170M5690

Eaton

FUSE 315A 1250V 2FU/115

0

170M5447

170M5447

Eaton

FUSE SQUARE 700A 1.3KVAC RECT

0

170M6542

170M6542

Eaton

FUSE SQUARE 500A 1.3KVAC RECT

0

170M5068

170M5068

Eaton

FUSE SQUARE 1.25KA 700VAC RECT

0

C10G1I

C10G1I

Eaton

FUSE CARTRIDGE 1A 500VAC CYLINDR

0

BK/KTK-R-1-1/2

BK/KTK-R-1-1/2

Eaton

FUSE CARTRIDGE 1.5A 600VAC 5AG

0

FWP-40A14FI

FWP-40A14FI

Eaton

FUSE CARTRIDGE 40A 700VAC/800VDC

0

LPJ-20SP

LPJ-20SP

Eaton

FUSE CARTRIDGE 20A 600VAC/300VDC

8

FWH-1400A

FWH-1400A

Eaton

FUSE CARTRIDGE 1.4KA CYLINDRICAL

0

BK/KTK-R-3

BK/KTK-R-3

Eaton

FUSE CARTRIDGE 3A 600VAC 5AG

0

170M6650

170M6650

Eaton

FUSE SQUARE 1.25KA 1.3KVAC RECT

0

170M1417

170M1417

Eaton

FUSE SQUARE 100A 700VAC RECT

6

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems

RFQ BOM Call Skype Email
Top