Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
0CNN350.V

0CNN350.V

Wickmann / Littelfuse

FUSE STRP 350A 125VAC/48VDC BOLT

21

0HEV010.ZXPCBL

0HEV010.ZXPCBL

Wickmann / Littelfuse

FUSE CERAMIC 10A 450VDC 5AG

460

170M6148

170M6148

Eaton

FUSE SQUARE 1KA 1.3KVAC RECT

0

0090.0005

0090.0005

Schurter

FUSE CARTRIDGE 5A 1KVDC 5AG

0

170M3111

170M3111

Eaton

FUSE SQUARE 80A 700VAC RECT

0

170M3609

170M3609

Eaton

FUSE SQUARE 50A 700VAC RECT

0

170M3110

170M3110

Eaton

FUSE SQUARE 63A 700VAC RECT

0

JLLN030.T

JLLN030.T

Wickmann / Littelfuse

FUSE CARTRIDGE 30A 300VAC/160VDC

0

FNQ-2-1/2

FNQ-2-1/2

Eaton

FUSE CARTRIDGE 2.5A 500VAC 5AG

0

170M5363

170M5363

Eaton

FUSE SQUARE 700A 700VAC RECT

0

170M6464

170M6464

Eaton

FUSE SQUARE 1KA 700VAC RECT

0

LVSP0080TX2

LVSP0080TX2

Wickmann / Littelfuse

FUSE CARTRIDGE 80A 600VAC

0

170M3661

170M3661

Eaton

FUSE SQUARE 80A 700VAC RECT

0

PSR033DS1400X

PSR033DS1400X

Wickmann / Littelfuse

FUSE SQUARE 1.4KA 700VAC/500VDC

0

KLKD030.T

KLKD030.T

Wickmann / Littelfuse

FUSE CARTRIDGE 30A 600VAC/VDC

86

16CT

16CT

Eaton

FUSE CARTRIDGE 16A 690VAC/500VDC

0

FWP-10B

FWP-10B

Eaton

FUSE CARTRIDGE 10A 700VAC/VDC

0

170M6620

170M6620

Eaton

FUSE SQUARE 1.8KA 700VAC RECT

0

157.5701.6171

157.5701.6171

Wickmann / Littelfuse

FUSE STRIP 175A 48VDC BOLT MOUNT

0

170M3664

170M3664

Eaton

FUSE SQUARE 160A 700VAC RECT

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems

RFQ BOM Call Skype Email
Top