| Image | Part Number | Description / PDF | Quantity | Rfq |
|---|---|---|---|---|
|
E-T-A |
CIR BRK THRM-MAG 8A 277VAC/60VDC |
0 |
|
|
|
E-T-A |
CIR BRKR THERM 1.5A 277VAC/60VDC |
0 |
|
|
|
E-T-A |
CIR BRK THERM-M 15A 277VAC/60VDC |
0 |
|
|
|
E-T-A |
CIR BRKR THRM 7A 240VAC 28VDC |
0 |
|
|
|
E-T-A |
CIR BRKR THRM 25A 115VAC 28VDC |
9 |
|
|
|
E-T-A |
CIR BRKR THRM 60A 115VAC 28VDC |
135 |
|
|
|
E-T-A |
CIR BRK THRM-MAG 5A 277VAC/60VDC |
0 |
|
|
|
E-T-A |
CIR BRK THERM-M 13A 277VAC/60VDC |
0 |
|
|
|
483-G533-J1M1-B2S0ZN-270018-40A E-T-A |
CIR BRKR THRM 40A 115VAC 28VDC |
0 |
|
|
|
E-T-A |
CIR BRKR THERM 10A 480VAC/125VDC |
0 |
|
|
|
E-T-A |
CIR BRKR THERM 63A 480VAC/125VDC |
0 |
|
|
|
E-T-A |
CIR BRK THRM-MAG 5A 277VAC/60VDC |
0 |
|
|
|
E-T-A |
CIR BRKR THERM 10A 480VAC/125VDC |
0 |
|
|
|
E-T-A |
CIR BRKR THRM 8A 250VAC 50VDC |
0 |
|
|
|
E-T-A |
CIR BRKR THRM 30A 32VDC |
155 |
|
|
|
E-T-A |
CIR BRK THERM-M 7A 480VAC/125VDC |
0 |
|
|
|
E-T-A |
CIR BRKR THRM 5A 250VAC 50VDC |
10 |
|
|
|
E-T-A |
CIR BRKR THERM 35A 480VAC/125VDC |
0 |
|
|
|
E-T-A |
CIR BRKR THERM 32A 480VAC/125VDC |
0 |
|
|
|
E-T-A |
CIR BRKR THRM SWITCH 10A IP65 |
9 |
|
Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.
| Type | Function Features | Application Examples |
|---|---|---|
| MCB (Miniature Circuit Breaker) | Thermal-magnetic protection, <100A rating | Residential wiring, lighting circuits |
| MCCB (Molded Case Circuit Breaker) | Adjustable trip settings, 10-2500A rating | Industrial machinery, HVAC systems |
| ACB (Air Circuit Breaker) | High fault current interruption, 400-6300A rating | Power distribution in data centers |
| RCCB (Residual Current Circuit Breaker) | Earth leakage protection (5-500mA sensitivity) | Outdoor outlets, swimming pool equipment |
| RCBO (Residual Current Breaker with Overcurrent) | Combines overload, short-circuit, and leakage protection | Hospital equipment, construction sites |
Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators
| Parameter | Description | Importance |
|---|---|---|
| Rated Current (In) | Maximum continuous current without tripping | Determines load capacity |
| Rated Voltage (Un) | Maximum operating voltage | Ensures insulation safety |
| Breaking Capacity (Icu) | Maximum fault current interrupting capability | Prevents catastrophic failure |
| Tripping Characteristics | Time-current curve (B/C/D types) | Matches load requirements |
| Pole Number | 1P to 4P configurations | Determines phase protection |
| Manufacturer | Representative Product | Key Features |
|---|---|---|
| Schneider Electric | Acti 9 series | Modular design, 0.5-125A range |
| Siemens | 5SJ series | High short-circuit withstand, DIN rail mount |
| ABB | Emax series | Smart connectivity, up to 6300A |
| General Electric | THQL series | UL-certified, industrial motor protection |
Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity
Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure