Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9974411902

9974411902

Weidmuller

CBH8342-10 20A W/O AUX

0

SU3C25UC

SU3C25UC

Weidmuller

CB PROTECTOR 1077 3P C 25A ACDC

16

9926252016

9926252016

Weidmuller

CIR BRKR MAG-HYDR 16A 240VAC

22

9129593200

9129593200

Weidmuller

CIR BRKR 800MA 250VAC 80VDC

0

9926251720

9926251720

Weidmuller

QY-1-13-DM-OP-20

85

9922251100

9922251100

Weidmuller

CB2212-10 W/NC AUX F1 25A

0

9913020003

9913020003

Weidmuller

CIR BRKR 200MA 480VAC 65VDC

0

9926252500

9926252500

Weidmuller

QZ-2-13-D-2-005

0

9922250002

9922250002

Weidmuller

CB2212-1O W/O AUX 25A

0

9926272005

9926272005

Weidmuller

CIR BRKR MAG-HYDR 5A 240VAC

0

9926241106

9926241106

Weidmuller

QZ-1-13-D-3-06

0

9926241110

9926241110

Weidmuller

QZ-1-13-D-3-10

0

BR1C35UC

BR1C35UC

Weidmuller

CB MCB 489 1P C 35A ACDC

180

9926271510

9926271510

Weidmuller

CIR BRKR MAG-HYDR 10A 240VAC

0

9926291140

9926291140

Weidmuller

QF17A40 - CB W/GFI

0

SU3D35UC

SU3D35UC

Weidmuller

CB PROTECTOR 1077 3P D 35A ACDC

12

9926251225

9926251225

Weidmuller

QL-1-13-DM-1-25

0

9911251100

9911251100

Weidmuller

2210-T210-K0F1-H131-2.5A

0

9911050002

9911050002

Weidmuller

CB2211-10-W/O AUX O.5A

0

9926283501

9926283501

Weidmuller

CIR BRKR MAG-HYDR 1A 480VAC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure