Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1278780000

1278780000

Weidmuller

CIRCUIT BREAKER THRM 8A 28VDC

0

9926273501

9926273501

Weidmuller

CIR BRKR MAG-HYDR 1A 480VAC

0

6720005388

6720005388

Weidmuller

CIR BRKR THRM 8A 24VDC SLD SWCH

19

9124333200

9124333200

Weidmuller

CIR BRKR 1.8A 250VAC 80VDC

0

9974371902

9974371902

Weidmuller

CBH8341-10 30A W/O AUX

0

BR3D32UC

BR3D32UC

Weidmuller

CB MCB 489 3P D 32A ACDC

70

SU1C60UC

SU1C60UC

Weidmuller

CB PROTECTOR 1077 1P C 60A ACDC

12

SU1C35UC

SU1C35UC

Weidmuller

CB PROTECTOR 1077 1P C 35A ACDC

12

9926273520

9926273520

Weidmuller

CIR BRKR MAG-HYDR 20A 480VAC

0

9921251302

9921251302

Weidmuller

CB2211-10 W/O AUX T1 25.0A

0

9921120005

9921120005

Weidmuller

CIR BRKR 12A 480VAC 65VDC

0

9911050005

9911050005

Weidmuller

CIR BRKR 500MA 480VAC 65VDC

16

9911301102

9911301102

Weidmuller

CB2211-10 3A W/O AUX. FAST ACT

0

9911301300

9911301300

Weidmuller

CIR BRKR THRMMAG 3A 277VAC 65VDC

0

BR2D6UC

BR2D6UC

Weidmuller

CB MCB 489 2P D 6A ACDC

12

9974381702

9974381702

Weidmuller

ETA 8340 T120 K1K2 AEHO 5A

0

6720005383

6720005383

Weidmuller

ESX10-TB-124-DC24V-3A-E

5

9926273002

9926273002

Weidmuller

QL-T-3(13)-DM-KM-2A

0

9921201102

9921201102

Weidmuller

CB2210-20 F1 W/O AUX. 20A

0

BR1D32UC

BR1D32UC

Weidmuller

CB MCB 489 1P D 32A ACDC

12

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure