Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
LMLB1-1RLS4-35530-8-V

LMLB1-1RLS4-35530-8-V

Sensata Technologies – Airpax

CIR BRKR MAG-HYDR LEVER

6

4230-T130-K0BE-5A

4230-T130-K0BE-5A

E-T-A

CIR BRK THERM-M 5A 480VAC/125VDC

0

GMS-32S-26A

GMS-32S-26A

Carlo Gavazzi

MMS 32A STD BREAK 18-26A

5

4410.0076

4410.0076

Schurter

CIR BRKR THRM 4A 240VAC 28VDC

20

GMB632PC8

GMB632PC8

Carlo Gavazzi

CIR BRK THERM-M 8A 240VAC/125VDC

5

IULK1-1-51-30.0-01

IULK1-1-51-30.0-01

Sensata Technologies – Airpax

CIR BRKR MAG-HYDR 30A LEVER

0

ACBP-24-N-15A

ACBP-24-N-15A

OptiFuse

NO BRACKET-TYPE I AUTO,15A 24V

0

4230-T130-K0CU-2A

4230-T130-K0CU-2A

E-T-A

CIR BRK THERM-M 2A 480VAC/125VDC

0

UTE100E-FTU-100-3P-LL-UL

UTE100E-FTU-100-3P-LL-UL

American Electrical, Inc.

CIR BRK THERM 100A 600VAC/500VDC

5

3C25UL

3C25UL

Altech Corporation

CIR BRKR THRM-MAG 25A LEVER

26

W57-XB7A4A10-10

W57-XB7A4A10-10

TE Connectivity Potter & Brumfield Relays

CIR BRKR THRM 10A 250VAC

1226

2-5700-IG1-P10-1372-38A

2-5700-IG1-P10-1372-38A

E-T-A

CIRC BRKR THRM

0

4435.0016

4435.0016

Schurter

CIR BRKR THRM 5A 240VAC ROCKER

5

W67-X2Q12-10

W67-X2Q12-10

TE Connectivity Potter & Brumfield Relays

CIR BRKR MAG-HYDR 10A 277VAC

147

CBW58-HS-30A-5C

CBW58-HS-30A-5C

OptiFuse

CIR BRKR THRM 30A 250VAC 50VDC

128

IULK1-1-53-65.0-01

IULK1-1-53-65.0-01

Sensata Technologies – Airpax

CIR BRKR MAG-HYDR 65A LEVER

0

0903025

0903025

Phoenix Contact

CIR BRKR SOLID STATE 3A 24VDC

9252

4435.0002

4435.0002

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

21

R21-2-15.0A-R123CV-V

R21-2-15.0A-R123CV-V

Sensata Technologies – Airpax

CIR BRKR MAG-HYDR 15A ROCKER

0

106-M2-P30-8A

106-M2-P30-8A

E-T-A

CIR BRKR THRM 8A 250VAC 48VDC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure