Wire Ducts, Raceways - Accessories - Covers

Image Part Number Description / PDF Quantity Rfq
T70CWH8

T70CWH8

Panduit Corporation

COVER RACEWAY PWR WHT 8'

480

NC75LG2

NC75LG2

Panduit Corporation

CABLE DUCT METRIC COVER 2M

28

HC4LG6

HC4LG6

Panduit Corporation

COVER HINGE DUCT PVC LTGY 6'

64

181-93005

181-93005

HellermannTyton

TC3 BLUE PVC DUCT COVER BULK

0

FRRASC6YL

FRRASC6YL

Panduit Corporation

6X4 HORIZONTAL RIGHT ANGLE SPLIT

382

C2IB6

C2IB6

Panduit Corporation

COVER DUCT PVC BLUE 2"X 6'

181098

C1WH6

C1WH6

Panduit Corporation

COVER DUCT 1" PVC WHITE 6'

16071700

T70FV2EI

T70FV2EI

Panduit Corporation

FACEPLATE SNAP ON VERT IVORY

38

181-92011

181-92011

HellermannTyton

WIRING DUCT COVER 2"X6'

23

C1.5LG6

C1.5LG6

Panduit Corporation

COVER DUCT 1.5" PVC GRAY 6'

23824306

DRDC2LG6

DRDC2LG6

Panduit Corporation

CABLE DUCT REPLACEMENT COVER 6'

10

C2BL6-F

C2BL6-F

Panduit Corporation

DUCT COVER PROTECTIVE FILM 6'

41

181-93003

181-93003

HellermannTyton

WIRING DUCT COVER 3"X6' 1PC=6'

0

C1LG6-F

C1LG6-F

Panduit Corporation

DUCT COVER PROTECTIVE FILM 6'

12565796

C4YL6

C4YL6

Panduit Corporation

COVER DUCT PVC YELLOW 4"X 6'

141308

C.75WH6

C.75WH6

Panduit Corporation

COVER DUCT .75" PVC WHITE 6'

2220466

PDC6IW6

PDC6IW6

Panduit Corporation

RACEWAY CVR PD6 LG OFWHT 6'

0

MCRFW-C8

MCRFW-C8

HellermannTyton

RACEWAY COVER 8'

0

C1.5WH6-F

C1.5WH6-F

Panduit Corporation

DUCT COVER PROTECTIVE FILM 6'

479540

MCRI-C8

MCRI-C8

HellermannTyton

RACEWAY COVER 8 FEET

0

Wire Ducts, Raceways - Accessories - Covers

1. Overview

Wire ducts, raceways, and their accessories (including covers) are critical components in electrical and data infrastructure systems. These products provide organized routing, protection, and management of cables, wires, and conduits. Covers specifically ensure safety by preventing accidental contact, dust ingress, and mechanical damage while enabling accessibility for maintenance. Their importance spans industries such as data centers, industrial automation, and commercial construction, where efficient cable management enhances system reliability and compliance with safety standards.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Split-type CoversEasily detachable design for retrofittingIndustrial control cabinets
Modular CoversInterlocking segments for scalable installationsData center cable trays
Fire-rated CoversIntumescent materials for fire resistanceCommercial building riser shafts
Flexible CoversRubber or elastomer materials for dynamic routesRobotics and moving machinery

3. Structure and Composition

Typical covers consist of a structural base (PVC, steel, or aluminum) combined with sealing gaskets or snap-fit mechanisms. Advanced models integrate ventilation slots for heat dissipation and cable entry cutouts for strain relief. Surface treatments include powder coating for corrosion resistance and UV stabilization for outdoor applications. Modular systems often feature interlocking edges and integrated mounting brackets.

4. Key Technical Parameters

ParameterKey SpecificationsImportance
Material TypePVC (flame-retardant), galvanized steel, aluminumDetermines mechanical strength and chemical resistance
Temperature Range-40 C to +120 C (standard)Ensures operational stability in extreme environments
IP RatingIP54 (dust/water protection)Defines environmental protection level
Load Capacity50-500 kg/m Crucial for overhead and floor-mounted installations

5. Application Fields

  • Data Centers: Cable management under raised floors
  • Industrial Automation: Protection of control cables in manufacturing
  • Commercial Buildings: Vertical riser cable containment
  • Transportation: Rail vehicle cable routing systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
PanduitPNC12-100F Modular CoverUL 94 V-0 fire rating, toolless installation
HellermannTytonCable Duct Cover 4501-0000Flexible TPE material, 180 opening
TE ConnectivityRAYDEX RDC-CV-50Aluminum alloy, 200 C heat resistance

7. Selection Recommendations

Key considerations include:

  • Environmental Conditions: Corrosive environments require stainless steel covers
  • Cable Compatibility: Diameter and quantity determine cover size selection
  • Accessibility Needs: Frequent maintenance requires quick-release designs
  • Fire Safety: Mandatory fire-rated covers in plenum spaces

Case Study: A German automotive plant reduced downtime by 30% after implementing modular covers with integrated cable strain relief in robotic welding stations.

Industry Development Trends

Emerging trends include:

  • Smart Covers: Embedded sensors for temperature and vibration monitoring
  • Eco-friendly Materials: Biodegradable composites replacing PVC
  • Standardization: Adoption of ISO 11341 for UV resistance testing
  • 3D-Printed Customization: On-site manufacturing for complex geometries
RFQ BOM Call Skype Email