Wire Ducts, Raceways - Accessories - Covers

Image Part Number Description / PDF Quantity Rfq
3240333

3240333

Phoenix Contact

COVER DUCT PVC BLUE 2M

0

HC1.5WH6

HC1.5WH6

Panduit Corporation

DUCT COVER PVC HINGED WHITE 6'

401224

NC1.5WH6

NC1.5WH6

Panduit Corporation

DUCT CVR HAL FREE WHT 1.5"X 6'

47

87171624

87171624

Murrplastik

BP 24 REINFORCED BLIND PLATE COV

75

181-92001

181-92001

HellermannTyton

WIRING DUCT COVER 2"X6'

48

C4LG6

C4LG6

Panduit Corporation

COVER DUCT PVC GRAY 4"W X 6'

11519890

3240372

3240372

Phoenix Contact

CABLE DUCT COVER

2

C3WH6-F

C3WH6-F

Panduit Corporation

DUCT COVER PROTECTIVE FILM 6'

55988

181-91000

181-91000

HellermannTyton

TC1 BLACK PVC DUCT COVER BULK 6'

0

FCL-21614

FCL-21614

Quest Technology International

WIREHIDER COVER LID 1/2'' WHT 6

575

T70CIW10

T70CIW10

Panduit Corporation

COVER RACEWAY PWR OFFWHT 10'

110

MCRI-C10

MCRI-C10

HellermannTyton

RACEWAY COVER 10 FEET

0

3240330

3240330

Phoenix Contact

COVER DUCT PVC BLUE 2M

0

FRHC4BL6

FRHC4BL6

Panduit Corporation

CABLE DUCT HINGED SNAP-ON 6'

564

C2.5BL6

C2.5BL6

Panduit Corporation

COVER DUCT PVC BLACK 2.5"X 6'

74198

3240332

3240332

Phoenix Contact

COVER DUCT PVC BLUE 2M

13

C1LG6

C1LG6

Panduit Corporation

COVER DUCT 1" PVC LTGRAY 6'

724133212

FCL-21414

FCL-21414

Quest Technology International

WIREHIDER COVER LID 1/2'' WHT 4

361

T70FH2WH

T70FH2WH

Panduit Corporation

FACEPLATE SNAP ON HORZ WHITE

24

181-94009

181-94009

HellermannTyton

WIRING DUCT COVER 4"X6'

0

Wire Ducts, Raceways - Accessories - Covers

1. Overview

Wire ducts, raceways, and their accessories (including covers) are critical components in electrical and data infrastructure systems. These products provide organized routing, protection, and management of cables, wires, and conduits. Covers specifically ensure safety by preventing accidental contact, dust ingress, and mechanical damage while enabling accessibility for maintenance. Their importance spans industries such as data centers, industrial automation, and commercial construction, where efficient cable management enhances system reliability and compliance with safety standards.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Split-type CoversEasily detachable design for retrofittingIndustrial control cabinets
Modular CoversInterlocking segments for scalable installationsData center cable trays
Fire-rated CoversIntumescent materials for fire resistanceCommercial building riser shafts
Flexible CoversRubber or elastomer materials for dynamic routesRobotics and moving machinery

3. Structure and Composition

Typical covers consist of a structural base (PVC, steel, or aluminum) combined with sealing gaskets or snap-fit mechanisms. Advanced models integrate ventilation slots for heat dissipation and cable entry cutouts for strain relief. Surface treatments include powder coating for corrosion resistance and UV stabilization for outdoor applications. Modular systems often feature interlocking edges and integrated mounting brackets.

4. Key Technical Parameters

ParameterKey SpecificationsImportance
Material TypePVC (flame-retardant), galvanized steel, aluminumDetermines mechanical strength and chemical resistance
Temperature Range-40 C to +120 C (standard)Ensures operational stability in extreme environments
IP RatingIP54 (dust/water protection)Defines environmental protection level
Load Capacity50-500 kg/m Crucial for overhead and floor-mounted installations

5. Application Fields

  • Data Centers: Cable management under raised floors
  • Industrial Automation: Protection of control cables in manufacturing
  • Commercial Buildings: Vertical riser cable containment
  • Transportation: Rail vehicle cable routing systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
PanduitPNC12-100F Modular CoverUL 94 V-0 fire rating, toolless installation
HellermannTytonCable Duct Cover 4501-0000Flexible TPE material, 180 opening
TE ConnectivityRAYDEX RDC-CV-50Aluminum alloy, 200 C heat resistance

7. Selection Recommendations

Key considerations include:

  • Environmental Conditions: Corrosive environments require stainless steel covers
  • Cable Compatibility: Diameter and quantity determine cover size selection
  • Accessibility Needs: Frequent maintenance requires quick-release designs
  • Fire Safety: Mandatory fire-rated covers in plenum spaces

Case Study: A German automotive plant reduced downtime by 30% after implementing modular covers with integrated cable strain relief in robotic welding stations.

Industry Development Trends

Emerging trends include:

  • Smart Covers: Embedded sensors for temperature and vibration monitoring
  • Eco-friendly Materials: Biodegradable composites replacing PVC
  • Standardization: Adoption of ISO 11341 for UV resistance testing
  • 3D-Printed Customization: On-site manufacturing for complex geometries
RFQ BOM Call Skype Email