Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
PMR5WH5

PMR5WH5

Panduit Corporation

WIRE DUCT SOLID FASTENER WHT 5'

0

G.75X1.5LG6N

G.75X1.5LG6N

Panduit Corporation

WIRE MANAGEMENT

0

G4X2IB6

G4X2IB6

Panduit Corporation

SLOTTED DUCT, PVC, 4"X2"X6',IBLU

0

OFR20MT6

OFR20MT6

Panduit Corporation

CABLE CHANNEL LOW VOLTAGE 6'

0

T45BWH2

T45BWH2

Panduit Corporation

PWR RATED MULTICHAN RACEWAY 2M

0

LDP3EI8-A

LDP3EI8-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE IVRY 8'

0

D4X4WH6

D4X4WH6

Panduit Corporation

WIRE DUCT ROUND SCREW WHITE 6'

0

TB170EI8

TB170EI8

Panduit Corporation

WIRE DUCT SOLID BASE SCREW 8'

0

FS.5X.5WH6

FS.5X.5WH6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW WHT 6'

0

PE4X4CL6

PE4X4CL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW CLEAR 6'

0

G4X5DG6

G4X5DG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

0

G2X4DG6

G2X4DG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

0

OFVR5OB6

OFVR5OB6

Panduit Corporation

SINGLE CHANNEL VERTICAL 6'

0

T70EI10

T70EI10

Panduit Corporation

WIRE DUCT SOLID BASE SCREW 10'

0

S2X2OR6

S2X2OR6

Panduit Corporation

FACEPLATE ACCESSORY

0

LDP3IG6-A

LDP3IG6-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE GRAY 6'

0

F4X4LG6N

F4X4LG6N

Panduit Corporation

WIRE MANAGEMENT

0

GC1X3LG2

GC1X3LG2

Panduit Corporation

WIRE MANAGEMENT

0

G3X2WH6-A

G3X2WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

PMR7WH5

PMR7WH5

Panduit Corporation

WIRE DUCT SOLID FASTENER WHT 10'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers