Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
S4X4WH6NM

S4X4WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

0

G2X1.5DG6

G2X1.5DG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

0

LDS3IG10-A

LDS3IG10-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE GRY 10'

0

NE4X3WH6-A

NE4X3WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

F4X2LG6-A

F4X2LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

G1X1LG6N

G1X1LG6N

Panduit Corporation

WIRE MANAGEMENT

0

F.75X1.5LG6N

F.75X1.5LG6N

Panduit Corporation

WIRE MANAGEMENT

0

LDP10WH6-A

LDP10WH6-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE WHT 6'

0

G.5X1DG6

G.5X1DG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

0

S.5X.5LG6NM

S.5X.5LG6NM

Panduit Corporation

WIRE DUCT SLOTTED GRAY 6'

0

TB105EI6

TB105EI6

Panduit Corporation

WIRE DUCT SOLID BASE SCREW 6'

0

FS4X5WH6NM

FS4X5WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

0

G4X4DG6

G4X4DG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

0

TB170IW6

TB170IW6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW WHT 6'

0

S3X3LG6NM

S3X3LG6NM

Panduit Corporation

WIRE DUCT SLOTTED GRAY 6'

0

S4X2LG6NM

S4X2LG6NM

Panduit Corporation

WIRE DUCT SLOTTED GRAY 6'

0

MC25X25IG20CM

MC25X25IG20CM

Panduit Corporation

WIRE MANAGEMENT

0

TB105IG8

TB105IG8

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 8'

0

MC100X62WH2

MC100X62WH2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

0

PE1.5X1.5CL6

PE1.5X1.5CL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW CLEAR 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email